Selection of refrigerant pipe
10 HP outdoor unit
L1=30m
Manifold pipe 1
L3=10m
a) Selection of diameter of refrigerant pipe
Refrigerant pipe portion Corresponding length of refrigerant pipe
L1
30
L2
10
L3
10
L4
5
L5
5
L6
5
L7
8
a
12
b
9
3
c
5
d
10
e
f
6
g
5
5
h
i
3
j
10
b) Selection of manifold pipe
Manifold portion
Manifold pie 1
Manifold pie 2
Manifold pie 3
Manifold pie 4
Manifold pie 5
Manifold pie 6
Manifold pie
L2=10m
a=12m
28
AS092FEAHA AS122FEAHA AS182FEAHA
L4=5m
f=6m
Manifold
Manifold
pipe 2
pipe 3
56
AS182FEAHA
Selection method of refrigerant pipe
Refrigerant pipe of outdoor unit is same as (Table 1)
1+1.25+2+0.8+0.8=5.08 (Table 2)
2+1.25+1+0.8+0.8=5.85 (Table 2)
1.25+1+0.8+0.8=3.85 (Table 2)
1+0.8+0.8=2.6
(Table 2)
0.8+0.8=1.6
(Table 2)
0.8+0.8=1.6
(Table 2)
Refrigerant pipe of indoor unit is same as (Table 3)
Refrigerant pipe of indoor unit is same as (Table 3)
Refrigerant pipe of indoor unit is same as (Table 3)
Refrigerant pipe of indoor unit is same as (Table 3)
Refrigerant pipe of indoor unit is same as (Table 3)
Refrigerant pipe of indoor unit is same as (Table 3)
Refrigerant pipe of indoor unit is same as (Table 3)
Refrigerant pipe of indoor unit is same as (Table 3)
Refrigerant pipe of indoor unit is same as (Table 3)
If it exceeds 30 m after first branch, the diameter of pipe of gas side should be increased 1 #.
Selection method of manifold portion
L2(5.85)+L3(5.85)=11.7(Table 4)
L3=5.85(Table 4)
L4=3.85(Table 4)
L5=2.6(Table 4)
L6=1.6(Table 4)
L7=1.6(Table 4)
For 4 manifold (Table 4)
Unit used Outdoor unit
Indoor unit
Manifold pipe end
L7=8m
b=5m
c=3m
Manifold
pipe 6
36
56
L6=5m
L5=5m
h=5m
g=5m
Manifold
Manifold
pipe 4
pipe 5
28
36
AS122FEAHA
AS092FEAHA AS072FEAHA AS072FEAHA
Gas side
*28.6
*19.0
*19.0
*15.9
*15.9
*15.9
*15.9
*12.7
*12.7
*15.9
*12.7
*12.7
*15.9
*12.7
*12.7
*12.7
*12.7 *15.9
23
: http://splitoff.ru/tehn-doc.html
AU96NFTAHA x 1 set
AS182FEAHA x 2 sets
AS122FEAHA x 2 sets
AS092FEAHA x 2 sets
AS072FEAHA x 4 sets
Total: 10 sets
e=10m
28m
d=5m
22
22
AS072FEAHA
AS072FEAHA
30m
i
j=10m
=5m
35m
22
28m
22
Liquid side
*12.7
*9.5
*9.5
*9.5
*9.5
*9.5
*9.5
*6.4
*6.4
*9.5
*6.4
*6.4
*9.5
*6.4
*6.4
*6.4
*6.4
Model of manifold portion
FQG-B370
FQG-B180
FQG-H3704