Wiring Diagram Of Au55Nfuaha Outdoor Unit - Haier AU96NFTAHA Service Manual

Hide thumbs Also See for AU96NFTAHA:
Table of Contents

Advertisement

c. Wiring diagram of AU55NFUAHA outdoor unit
Y
L2
reactor line
assembly
L1
R
Y
BL
reactor
6
12
6
3
4
5
11
5
1
noise filter
4
10
4
1
2
3
9
3
2
8
2
Y
BL
1
7
1
R
(+)
(-)
3
rectifier
(-)
(-)
(-)
R
R W B
R
R
PTC
PTC
1
2
2
4
6
B
3
4
R
52C3
1
3
5
A
P03
R
R
W
P02
W
surge
2
4
6
B
P01
B
absorber
MCC-1253
52C1
P04
B
1
3
5
A
F3
F2
R
W
B
4
5
6
3
noise filter
1 2 3
R W B
F1
R
R
W
B
surge absorber
L1 L2
L3
N
Power 380V- 415V,3N~,50Hz
Function explanation of dial switch(MCC-1332)
Code
Name
Compressor (inverter)
SW01 SW02
CM1
0
52C1
Magnetic contactor(CM1)
52C3
Magnetic contactor(CM1)
electronic expansion valve
PMV
63H1
high-tension switch
RC01
capacitor (for FM 01)
1 2
SV1,SV2
2way-valve solenoid valve
20SF
4way-valve solenoid valve
*
*
CH
crankcase heater for compressor
309
309
F1,F2,F3
fuse(20A 600V)
49C1
inside overload protector(IOL)
TD1,TS,TE
temp sensor
TRS
thermostat (100*)
1
Notes:please connect the outdoor unit to the power,
then connect the indoor unit to the power,
otherwise,the failure code[95]may appear.
At this time,press the "self-check"button on the
wired controller for at least 10 senconds to delete
the failure code.(The machine's operation will
not be influenced by such a phenomenon)
pressure sensor
pressure sensor
low pressure(Ps)
high pressure(Pd)
2
2
6
4
2
1
6
4
1
5
4
3
1
4
W
R
BL
2
2
1
3
2
1
6
4
1
6
4
5
4
4
W
12
11
BL
W
BL
CN07
CN08
CN17
CN28
10
3
3
9
CN01
8
GR
1 1
7
TD1
R
3
4
noise
filter
3
3
1
2
CN02
R
1 1
GR
W
noise filter
2
2
CN03
1 1
TS
BL
2
2
CN05
1 1
TE
W
MCC-1332
3
3
CN14
1 1
W
5
5
4
4
CN10
3
3
2
2
CN06 CN18 CN51 CN50
CN24
CN25
1
1
1
2
1
3
1
3
5
1
3
R
W
W
1
2
1
3
1
3
5
1
3
R
GR
R
RC01
BL OR Y R W
W R BL B
1
3
4
5
6
1
2
3
4
PMV
W
FM1
W
P Q
1
3
4
5
6
1
2 3
4
shielding line earthing
PMV
FM1
P Q
Displayed Information
0
failure code for outdoor unitng
SW01 SW02
1
operational mode,cooling:C,heating:H,defrost
1
external instruction operation state,external instruction operation: 1
3
4
INV target frequency
2
operation mode of extermal option,cooling:c heating:h
5
INV real frequency
3
intergrated operation start and stop: start:1, stop: 0
6
number of the indoor units connceted
4
control state of fan speed prevent snowing in control: 1
7
out door unit is in the sensor back-up operational state
control state of low noise operation at night control: 1
5
9
confirm mis-wired (cooling operation),press sw04 for at least 2 seconds
10
confirm mis-wired (heating operation),press sw04 for at least 2 seconds
11
cooling test run,press SW04 at least 2 seconds
12
heating test run,press SW04 at least 2 seconds
SW01
SW02
14
integrated operation start and stop start:11 stop:00 normal:--
4
0-15
room units communication state information receiving: 1
confirm operation of indoor remote controller:start:11 normal:--
15
5
0-15
room units failure code
0
6
0-15
data of TD1
room units capacity code
0-15
2
data of TS
10
room units PMV open degree
3
data of TE
12
0-15
room units TA sensor data
4
13
0-15
data of Pd
room units TC2 sensor data
5
data of Ps
14
0-15
room units TCIA sensor data
6
PMV open degree of outdoor unit
16
0-15
room units separate test run start:11,stop:00
(The"0~16"under SW02 is the addresses of indoor unit)
19
4
3
2
1
4
3
1
5
4
3
2
1
3
2
1
2
8
7
6
BL
W
R
W
4
3
2
1
4
3
2
1
8
5
4
3
2
1
3
2
1
7
6
CN27
CN09
CN13
B
D42
D43
3
3
CN15
1 1
SW01 SW02 SW07
B
ON
4
4
3
3
CN11
2 2
1
2
3
1 1
ON
1
2
3
SW04 SW05
ON
SW03
SW06
B
7
7
5 5
CN16
3
3
1 1
W
5
5
CN12
3 3
1 1
CN19
CN20
5
1
3
5
7
3
5
W
W
R
5
1
3
5
7
3
5
BL
B B B B B B OR
B
PU
R
1
2
3
5
6
7
1
2
SV1,SV2
W
4WV
W
2
3
1
5
6
7
1
2
SV1
20SF
SV2
displayed information
SW
Unit
Function
03
1
Not used
2
Not used
3
external control function switch
1
Back-up operation on Pd sensor in failure back-up operation
Back-up operation on PS sensor in failure back-up operation
06
2
3
Not used
07
1
Not used
Switch SW01 & LED Displayed Information(MCC-1331)
displayed information
Switch
1 red (D25)
2 yellow (D26)
Overcurrent protective
1 2
compressor system
ON
circuit of GTR
circuit
1 2
current detect
ON
circuit
1 2
ON
Frequency data of serial signal(receiving from MCC-1332)
1 2
ON
Frequency data of serial signal(sending to MCC-1332)
: http://splitoff.ru/tehn-doc.html
Y
+
B
resistor
G-Tr
W
R
-
W
V
U
capacitor
B
R
+
+
BL
diode
EZ BZ EY BY EX BX
_
_
B
+
resistor
-
EW BW EV BV EU BU
capacitor
1 2 3 4
1 2 3 4
D
,
C,current sensor
BL
B
R
B
resister
resister
resister
B
W
1
3
1
3
1
3
B
W
R
1
3
1
3
1
3
CN24
CN23
CN22
Y
P01
MCC-1252
P02
BL
CN20
1
3
1
2
3
4
BL
1
3
1
2
3
4
R
GR
1
2
3
4
1
2
3
4
B
B
D25 D26 D27 D28
3
3
CN06
R
A C, current sensor
1 1
B
B
4
4
B
3
3
B
CN07
2 2
B
1 1
MCC-1331
BR
3 3
CN15
1
1
CN17
CN16
CN05
TRS
1
3
1
3
1
2
3
4
5
6
8
7
W
BL
1
3
1
3
BL
R
Y
R
B
1
3
2
1
CH
R 63H(INV)
BL
1
1
3
2
63H1
CH
49C1
ON
OFF
normal
1. Dotted line for fiels wiring.2.
normal
external control snowing fan control
normal
normal
normal
normal
LED
3 yellow (d27) 4 yellow (D28)
high-pressure
current detect
switch system
protection
circuit
times of protective
action
R
diode
B
B
BL
W
R
1
1
3
3
5
5
7
7
W
1
1
3
3
5
5
7
7
CN25
CN21
5
6
7
8
9
5
6
7
8
9
5
6
8
9
7
W
5
6
7
8
9
CN01
W
SW01
R
4
4
R
3
3
CN13
Y
2 2
B
1 1
R
W
3
3
W
CN18
1 1
W
OR
3
3
Y
CN04
CN12
2
2
BL
1 1
1
3
5
W
1
3
5
OR B
R
U V W
R W B
CM1
inverter
for terminal black the numbers inside for the terminal numbers.3.