Haier AU96NFTAHA Service Manual page 122

Hide thumbs Also See for AU96NFTAHA:
Table of Contents

Advertisement

Category
Repair part
Electronic
control
expanding
valve coil
Pressure
sensor
Step (Sequence)
AB092FEAIA
AB122FEAIA
AB142FEAIA
AB162FEAIA
*1 Remove the fixing plate for refrigerant pipe 2. Remove the water tray
3. Remove the electronic expanding valve
*1. Remove the cover of refrigerant pipe and
fixing plate
2. Remove the water tray
3. Remove the evaporator
4. Remove the pressure sensor having fault
with welding method, and weld the new
pressure sensor to the original position
AB182FEAIA
AB242FEAIA
AB282FEAIA
AB322FEAIA
1. Remove the electronic
expanding valve coil with
double-head wrench, do not
tighten the expanding valve
excessively
2. The fixing nut for electronic expanding valve
3. Once the coil is removed, it
should not be used again
(otherwise the expanding valve
may be damaged)
Avoid welding block and through
penetration
119