Installing method of convertible type unit
(1). Arrange the wall outlet hole and install the support fixinghole according to the following diagram; drill*10 x 60 holeon the pos
(2).
Fix the support
As shown in the diagram, fix the support with expansion bolt.
(3).
Install indoor unit
First, install the bolts at both sides of the indoor unit as shown in the diagram, then, install theindoor unit according to the meth
indoor unit
(4).
Install drainpipe
For the installing method and leading-out direction of the drainpipe, please refer to the previous pages.
Note: the drainpipe should be lower than the connecting portion where it is connected to the indoor unit
as shown in the following diagram:
than the connecting portion
where it is connected to the
indoor unit
bolt
8-13mm
make the drainpipe lower
correct
Model
Liquid pipe (mm)
AC182FEAHA
AC242FEAHA
AC182FEAHA, AC242FEAHA
1244mm
326mm
selectable position for wall outlet hole
drainpipe
Gas pipe (mm)
*9.52
*15.88
*9.52
*15.88