Troubleshooting

Fault
Water changes
color or becomes
cloudy.
Rowing stroke
return is too light.
Rower rocks from
side to side when
sitting on floor
Front of Rower lifts
slightly during
vigorous rowing.
Monitor screen illu-
minates, but does
not register when
rowing.
Monitor does not
illuminate after bat-
tery installation.
Monitor display is
erratic while dis-
playing SPM and
500meter times.
Excessive frame flex
during hard rowing.
Monitor LEVEL is
not synchronized
with the Tank LEV-
EL.
Probable Cause
Rower is in direct
sunlight or has not
had water
treatment.
Bungee not under
enough tension.
Front/Rear frame
levelers need
adjusting
Lower rear frame
leveler too high.
Loose or failed
connection/Sensor
gap too wide (see
erratic monitor
display).
Batteries installed
incorrectly or need
replacing.
Gap between
Sensor and
Magnetic Ring is
too wide.
Frame Tension
Cable is too loose
Monitor LEVEL
needs to be recali-
brated.
Solution
Change Rower location to reduce direct
exposure to sunlight. Add water treatment
or change Tank water as directed in the water
treatment section of this manual. Consider
using distilled water to refill Tank.
Open rear Perspex cover, cut Bungee tie
wrap. Tighten by small increments using the
Bungee tie off tab point and test tension by
allowing the rowing handle to return to its
furthest point forward while still having some
slight tension. Note light fraying of the
Bungee cord is normal.
Adjust the front two frame levelers or rear leg
levelers until stability is reached. Note: It is
normal for the lower rear leveler to rest
slightly off the floor.
Check to see that frame tensioning Bolt is
tightened properly. Lower rear frame leveler
should be approx. 5mm off the ground.
Check that the monitor lead is connected
properly. If connected properly check sensor
gap. Contact your local service center if this
fails to address the problem.
Reinstall batteries in correct position and try
again. If the LCD screen fails to illuminate,
try rotating the batteries slightly in the
monitor. If this fails, contact your local ser-
vice center.
Adjust Sensor location using rear sliding
adjustment located inside rear Perspex
cover.
Loosen frame tension cable Retaining Nut and
tighten cable until taut.
Please refer to "Calibration Procedure" page
19 of this manual.