Download Print this page
Von Duprin 377-T Installation Instructions

Von Duprin 377-T Installation Instructions

Advertisement

Quick Links

*941116-00*
941116-00
Control for Metal Door Application
1. Prepare door for exit device. See exit
device instructions for locations of
holes, backset (line X-X), and center
lines.
2. Prepare door for control:
A. Transfer line X-X from inside (exit
device side) of door to outside
(control side) of door. Use extra
care if edge of door is beveled.
Be sure line X-X is parallel to edge
of door.
B. Locate and prepare holes as
indicated.
3. Install cylinder if required (Figs. 1 &2).
Insure cylinder cam is set for required
function and replace if necessary.
4. Install control and rub plate (Fig. 2)
5. Slip rod member on top rod.
6. Install top rods (see direction for
vertical rod device).
7. Position rod member so finger contacts
cam when top latch bolt is extended.
8. Tighten set screws in rod member.
9. Apply device and test key, control,
and device action.
377-T & 377-T-BE
X
1/2" dia.
Omit cylinder
for BE function
11/16" R, 2 places
(omit for BE)
3"
6-1/4"
1-7/8"
1-3/8" dia.
(BE only)
Outside
X
face of
lock stile
For cutouts on inside face
of door see instructions in
device carton
Line X-X corresponds to line X-X on exit device instructions
2 places
53-1/2" to
finished floor
Device Application Schedule
4427, 8827, 8827-F Vertical Rod Exit Device
Customer Service
1-877-671-7011
www.allegion.com/us
Installation Instructions
LHR shown
RHR opposite
1/8"
C L
of thumbturn
1"
R
2 places
1/4"-20 tap
2 holes
X
5/16" dia.
2 places
5/8"
1-1/4"
2-7/8"
Inside
X
face of
lock stile
© Allegion 2014
Printed in U.S.A.
941116-00 Rev. 01/14-b

Advertisement

loading
Need help?

Need help?

Do you have a question about the 377-T and is the answer not in the manual?

Questions and answers

Summary of Contents for Von Duprin 377-T

  • Page 1 *941116-00* 377-T & 377-T-BE 941116-00 Control for Metal Door Application Installation Instructions Line X-X corresponds to line X-X on exit device instructions 1. Prepare door for exit device. See exit device instructions for locations of holes, backset (line X-X), and center lines.
  • Page 2 Hexagon mounting Socket set extension screw Mortise cylinder Cylinder nut Cylinder locating washer member Cylinder cam in Rub plate this position with key removed TL Function - Control remains unlocked when key is removed NL Function - Control relocks when key is removed.

This manual is also suitable for:

377-t-be