Fig. 21
11. Attach the fl ue pipe adapter (Fig. 21A). Secure the fl ue pipe
adapter with a bit of tape so that it does not fall down. The
convection chamber is now ready to be placed inside the
heart/surround. If installing a fan, this must be done now. A
separate instruction manual is provided with the
Fig. 22
12. Put the convection chamber into place. If no hot air ducts
are being installed, the entire product can be put into
16
Fig. 23
A
A
13. See Fig. 10 and 11 if the entire product is placed inside the
surround/hearth.
14. Adjust the 4 leg screws (Fig. 23A) using the 4 mm Allen key
from the bag of screws until the product is level.
15. Test to see whether the frame (Fig. 12) fi ts and check that
the fl ue pipe adapter is aligned with the middle hole in the
convection chamber.
16. Drill 2 Ø10 mm plug holes (Fig. 23B) in the hearth and secure
the convection chamber in place with screws and washers from
fan.
the bag of screws.
17. If these screws do not grip well, there are two other
attachment options below the heat shield (Fig.
Fig. 24
18. Attach each hot air duct to the convection chamber using 3
tapping screws (Fig. 24A) from the bag of screws.
19. Place the burn chamber (Fig. 18A) inside the convection
chamber and secure with the screws (Fig. 17 A).
place..
C
B
A
A
23C).