IBM i Series Handbook page 51

Connecting to operations console
Hide thumbs Also See for i Series:
Table of Contents

Advertisement

"Troubleshooting authentication problems" on page 94
|
|
When setting up your initial connection, you might encounter authentication problems.
|
"Troubleshooting emulator problems" on page 94
When setting up your initial connection you may encounter emulator problems.
|
"Troubleshooting status message" on page 87
|
|
If you encounter connection problems when connecting a console, Operations Console provides status
messages to assist you in troubleshooting the connections.
|
|
Activating the asynchronous communications line on the system:
These instructions apply only to configurations of a local console that is directly attached. To manually
|
|
activate the asynchronous communications line on the system, complete these steps:
|
1. If your system uses a keystick, insert it in the key slot now.
2. Place the system into manual mode by using the system's control panel.
|
3. Using Up and Down, select function 25 and press Enter.
|
4. Use Up to select function 26 and press Enter.
|
5. Use Down to select function 66 and press Enter.
|
Results
|
|
The system attempts to initialize the attached modem. If it is successful, the Function/Data window
displays D1008066. If the system could not initialize the modem, it displays D1008065.
|
Related tasks
|
|
"Failure to display D1008065 and D1008066 automatically after calling the function" on page 98
When working with models that have a double row for the Function/Data display portion of the
|
control panel, the control panel might not automatically display the resulting system reference code
|
|
(SRC).
|
Related reference
"Switching from one console type to another when a console is currently available" on page 51
|
If you know in advance that you will need a different console type, you can use the current console to
|
|
make the changes necessary for use with a different console.
Deactivating the asynchronous communications line on the system:
|
|
These instructions apply only to local consoles that are directly attached. To manually deactivate the
asynchronous communications line on the system, follow these steps:
|
|
About this task
1. If your system is not in manual mode, if the extended functions are not activated, or both, follow
|
these steps. Otherwise, go to Step 2.
|
|
a. If your system uses a keystick, insert it in the key slot.
|
b. Place the system into manual mode by using the system's control panel.
c. Using Up and Down, select function 25. Press Enter.
|
d. Use Up to select function 26. Press Enter.
|
2. Use Down to select function 65. Press Enter.
|
|
Results
|
If the deactivation is successful, the Function/Data window displays D1008065.
|
Related tasks