GAS CONNECTION
IMPORTANT: The connection must be executed by qualified technician according to the
relevant local standard.
The connection must be executed by qualified technician according to the relevant standard.
The fitting is made up of (see below figuration);
1 Elbow fitting "A"
1 adapter "B"
Gaskets "C","D"
A built in gas hob must be installed
in a room with adequate ventilation.
ORIENTATION of the ELBOW
The appliance is supplied with a gas connection oriented towards the centre of the built-in gas
hob. The connection to the gas supply must be effected only from this side or in vertical
position by turning the elbow downwards. To turn the elbow, follow these operations:
Loosen the nut
Turn the elbow
Lock the nut
Make sure that there are no
leakage by a soapy solution.
IMPORTANCES:
1.Never attempts to turn the elbow without having first slackened off the relative lock nipple.
2.The seals are the elements that guarantees the seal in the gas connection. It is
recommended that they be replaced whenever they shows even the slightest deformation or
imperfection.
3.After connecting to the mains, check that the couplings are correctly sealed, using soap
solution, but never a naked flame.
4.The connection with rigid metal pipes should not cause stresses to the bob ramp.
5.If the rubber tube is used for the gas connection:
Make sure the tube is snugly fit at both ends and use a standard tube clamp (not
supplied) to fasten it.
The rubber tube must be as short as possible, without contractions or kinks.
The rubber tube must never be at any point in its length in contact with the "hot" parts.
From time to time check to make sure that the rubber is in perfect condition.