4
Operators Familiarization
.
TO RECOVER A DELETED SETUP:
1. Select the Store/Recall Setup menu.
2. Rotate the
-+t
control clockwise until the last record Is displayed. That
record will have a status of M DELETED."
3.
Press RECALL to recall the front-panel settings
tot
I
the deleted
record.
4. Decide where you want to store the deleted setup. You can replace an
existing setup using the STORE function, or you can Insert a new setup
with the INSERT NEXT function.
a.
To replace an existing setup, rotate the
-+t
control to the setup
number that Is to be replaced and press the STORE button
.
b.
To Insert a new setup, rotate the
-+t
control to the setup number
that Is to precede the new setup and press the INSERT NEXT
button.
5.
Press AL TEA LABELS button
.
6. Alter the name and status of the new setup as desired. See
M
ALTER
LABELS" description In this section.
Storing Setups in Sequences
Front-panel setups are stored In the Store/Recall memory and numbered
starting at 01. A total of 20 setup records can be stored and recalled
.
Stored setups can be recalled Individually by setup number, or sequentially
within marked sequences. A sequence Is defined as
star.
t ing at setup
num-
ber 01 or the first record after one marked with a status of END SEQ and
ending with the next record with a status of END SEQ or the last stored
record.
To store a sequence of front-panel setups, perform the foll owing
procedure:
1. Set CONFIGURE In the Service Menu for the following:
KEEP MENU ON WHEN MEAS SELECTED
RECALL ONLY? (IN STORE/RECALL)
KEEP MENU ON WHEN S/R SELECTED?
YES or NO
NO
YES
3-50
2247 A Operators
I
I
I
I
I
I
2.
3.
4.
5.
6.
7.
Operators Familiarization
Press the STORE/RECALL SETUP button to call up the Store/Recall
Setup menu.
Rotate the
-+t
control to review the stored setups
.
Determine whether
there are enough EMPTY locations to store all of the setups In your
sequence. There are a total of 20 locations available. It Is a good Idea
to use only 19 and leave the 20th open so that the system will have a
place to store the last deleted file for recovery when necessary.
If there are not enough locations available to store your setups, you
can use DELETE to remove unneeded setups or you can use the
STORE function to "write" over them.
Set the front-panel controls as desired for the first setup In your
sequence. Set all controls the way you want them; even the Intensity
control settings can be stored for recall. You can set the front-panel
controls In several ways: setting the Individual controls manually,
Inputting the desired signals and pressing the AUTO SETUP button, or
by ~ecalllng and modifying an already storE~d setup.
Rotate the 41 control to the' setup location that Is to precede or start
the first setup In the sequence.
Press INSERT NEXT (or STORE, If the current setup location Is to be
"written" over).
Press AL TEA LABELS to call up the ALTER LABELS menu and give the
desired name to your setup. Also make sure that the status Is plank for
all of the setups In the sequence, except the last one, ang that one
should be END SEQ. END SEQ Is used to mark thp last setup In a
sequence using the ALTER LABELS function.
8. Press RETURN to display the Store/Recall Setup menu.
9. Repeat the above process of Inserting or storing (writing over) untll all
the setups In your sequence are stored In memory.
10. If your sequence did not begin at setup location 01, use the AL TEA
LABELS menu to alter the status of the setup just preceding your first
setup In the sequence to END SEQ.