Figure 16
Grounded outlet Box
Adapter
In Canada, the use of temporary adapter is not permitted
by the Canadian Electric Code. Where permitted, the rigid
green tab or terminal on the side of the adapter must be
securely connected to a permanent electrical ground such
as a properly grounded water pipe, a properly grounded
outlet box or a properly grounded wire system.
• Many cover plate screws, water pipes and outlet
boxes are not properly grounded. To ensure proper
ground, grounding means must be tested by a
qualified electrician.

EXTENSION CORDS

Use proper extension cords. Make sure the extension
cord is in good condition. Use only 3-wire extension cords
have 3-prong grounding type plugs and 3-pole receptacles
which accept the tool plug. When using an extension cord,
make sure to use one heavy enough to carry the current
of the machine. An undersized cord will cause a drop in
the voltage, resulting in loss of power and overheating.
Use the table to determine the minimum wire size
(A.W.G.) extension cord.
Extension Cord Length
Wire Size
Up to 25 ft
NOTE: Using extension cords over 25 ft. long is
not recommended.

MOTOR

The sander is equipped with a 2.3 Amps motor. The
120 Volt motor has the following specifications:
Horsepower .................................................................. 1/3
Voltage .........................................................................120
Amp ...............................................................................2.3
Hertz ...............................................................................60
Phase .......................................................................Single
RPM ............................................................................3450

ELECTRICAL CONNECTIONS

• Turn the switch off and disconnect the machine
from power source before performing any repair or
maintenance work.
• Some electrical wiring and connection work must be
performed by a qualified electrician in accordance with
local regulations.
• Scheme of the motor and electric wiring inside this
machine is shown in Figure 17.
• There is a green grounding wire fastened to the frame
Grounding
• The Motor is rated for use at 120 Volts.
Means
• Connect this machine to 3-Conductor Power outlet with
• Use only 3-pronged Extension Power Cord with
• When changing the power cord, use only 3-pronged
• The Power switch is a Single Pole Rocker switch with
Figure 17
A.W.G.
16
of the machine to provide Shock Protection. Do not
disconnect the Grounding Wire from the frame.
appropriate rating only.
appropriate rating with this machine.
Power Cord with appropriate rating.
Locking Mechanism. Remove the Key when not in use
to prevent accidents.
7