View Log - Abus AZWG10020 Installation And Operating Instructions Manual

Gsm/pstn dialer
Table of Contents

Advertisement

Available languages

Available languages

12.9 View Log

The device has an event log with a time and date stamp. Important system
events are logged here. The log can store 128 entries. The memory
operates as a non-volatile circular buffer, i.e.:
The entries are retained even when the power is interrupted
The oldest entries are overwritten with the newest entries when
the capacity is reached
Event
Memo Left
Memo Cleared
Trig A Alarm
Trig A Clear
Call Name 01
Ack Name 01
User Abort
Sys Restart
Temp H Alarm
Temp H Clear
Temp L Alarm
Temp L Clear
Meaning
Memo available
Memo was deleted
Triggering of input A
Inputs B–H analogously
Input A is again in the normal state
Inputs B–H analogously
Call to contact 1
Contacts 2-10 analogously
The contact name is displayed as programmed.
"Name 01" is the factory setting.
Acknowledgment of the message by contact 1
Contacts 2-10 analogously
The contact name is displayed as programmed.
"Name 01" is the factory setting.
Message is aborted using passcode
System start of device. The device was switched on.
The temperature has exceeded the preset upper
temperature limit
The temperature has fallen below the preset upper
temperature limit again
The temperature has fallen below the preset lower
temperature limit
The temperature has exceeded the preset lower
temperature limit again
49 UK

Advertisement

Table of Contents
loading

Table of Contents