Phone Line Fault:
The output is activated when a fault occurs on the
telephone connection.
The device requires about 50 s to register this fault.
PSTN In Use:
The output is activated when the device is active on the
analog telephone line.
GSM In Use:
The output is activated when the device is active on the
GSM cellular network.
Call Active:
The output is activated when the device triggers and a
dialing procedure has been started. The output is
deactivated after the device has called all contacts or if
the call is canceled.
Call Successful:
The output is activated when the device has transmitted
the message successfully. The output is deactivated
when the device is triggered again.
Call Failed:
The output is activated if the device could not transmit
the message successfully. The output is deactivated
when the device is triggered again.
Remote Control 1–4:
These outputs can be activated or deactivated remotely
over the telephone.
See also "Operation  Remote Access  Functions in
Remote Access Mode"
Supply Low:
The output is activated when the preset voltage
threshold is undershot. The output is deactivated when
the voltage rises above the defined threshold again.
See setting in "System Settings  Alarm Levels 
Supply Low"
Signal Low:
The output is activated when the preset signal strength
threshold is undershot. The output is deactivated when
the signal strength rises above the defined threshold
again.
See setting in "System Settings  Alarm Levels 
Signal Low"
The connected telephone line is disconnected
No voltage on the connected telephone line