Temperature Display
When the function is activated (ON), the display shows the current am-
bient temperature in degrees Celsius (default).
No temperature is displayed when this function is deactivated (OFF).
Phone Line Fault
Any telephone line faults are stored in the event memory.
Display Off
When this option is selected, the telephone line fault is only stored in the
event log (default).
Display On
When this option is selected, the device indicates every telephone line
fault on the display with "Phone Line Fault". No warning signal sounds.
Display and Beep
When this option is selected, the device indicates every telephone line
fault on the display with "Phone Line Fault", and the device beeps every
minute. To mute the tone if the fault persists, open the programming
menu.
Note: It can take up to 60 seconds before the fault is displayed.
12.3.5

Alarm Levels

High Temperature
In this function you can specify a maximum temperature above which an
output of type "High Temperature" switches (see also menu item "Outputs").
A value between 0 °C and 50 °C can be set (the default is 40 °C).
Low Temperature
In this function you can specify the minimum temperature below which an
output of type "Low Temperature" switches (see also menu item "Outputs").
A value between 0 °C and 50 °C can be set (the default is 5°C).
Supply Low
In this function, you can set the operating voltage level below which an
output of type "Low Voltage" switches (see also menu item "Outputs"). If the
operating voltage drops below this value, a "Low Voltage" message is stored
in the event memory. A value between 8 V and 24 V can be set (the default
is 10 V).
Signal Low
In this function, you can specify the GSM signal level below which an output
of type "Signal Low" switches (see also menu item "Outputs"). If the GSM
signal level falls below this value, a "Signal Low" message is stored in the
event memory. A value from 1 to 7 can be set (the default is 3). This is
equivalent to the bars of signal strength on a mobile device (see also menu
item Test Options  GSM Phone Utils  Signal Strength).
27 UK