Proper Installation - Maytag Amana PTC A Series Service Instructions Manual

Package terminal, air conditioners & heat pumps
Table of Contents

Advertisement

PROPER INSTALLATION

Minimum Interior and Exterior Projections
MINIMUM CLEARANCES AND PROJECTIONS
Option
A
in.
mm
Wall Sleeve Only
3
75
Subbase Kit
3
75
Leveling Legs Kit
3
75
Duct Kit
3
75
Drain Kit
3
75
Hard Wire Kit
3
75
Hydronic Heat Kit
9
230
"A" Series
Hydronic Heat Kit
6
150
"J" Series
1
If inside mounted then B = 1 1/2 inches (40 mm).
2
To achieve a flush fit between the hydronic front and the finished wall,
Dimension "C" must be between 3" and 3 1/8". If this dimension is more
than 3 1/8" there will be a gap between the front and the wall. This gap
could permit occupant access to hydronic lines or other dangerous parts.
3
This dimension can be from 0" to 3-1/4", but cannot exceed 3-1/4". If this
dimension exceeds 3-1/4", the skirt around the front will not reach the
floor.
• For installations in walls deeper than 13-1/2 inches, spe-
cial care is necessary to prevent problems with rain water,
condensate drainage and intake/discharge air. Under these
circumstances, careful job site analysis and precautions
are required. You must consult with your Sales Represen-
tative and receive approval before attempting such installa-
tions.
• If used, a 230/208 volt wall receptacle must be located
within 58 inches of the lower right sleeve corner. Exten-
sion cords must not be used with the unit. See the note on
Wall Sleeve Dimensions Figure.
Minimum
Minimum
Clearances
Projection
B
in.
mm
in.
0
0
0
3 1/4
85
2 3/4
3
75
2
0
0
1 3/8
1
1
0
0
0
1 1/4
30
0
3
3
32
0 to 3 1/4
0 to 85
0
0
2 1/2
Minimum Wall Opening Dimensions
When 230/208 volt units are to be installed, the power supply
may be either cord connected or permanent wiring. Permanent
wiring may be done through the accessory hard wire junction
C
box, or the accessory subbase.
mm
0
When 265 volt units are to be installed, the power supply must
70
be permanent wiring. Permanent wiring may be done through
50
the accessory hard wire junction box, or the accessory sub-
base. An exposed cord connection on 265 volt units is not
35
permitted.
0
0
The subbase accessory includes leveling legs. If added wall
752
sleeve support is required and the subbase is not to be used
as an accessory, leveling leg kit may be installed.
65
Drain Kit
An indoor/outdoor drain kit is available as an accessory item.
When a drain kit is to be installed, do so before installing the
wall sleeve in the wall. See the drain kit for actual installation
instructions.
Subbase, Leveling Legs, Main Duct, and Hydronic Heat
Kits
Installation of these kits requires drilling of mounting holes on
both sides of the wall sleeve. The minimum required clearance
distance between the wall sleeve and wall is shown in Mini-
mum Clearances and Projections Table. If the distance be-
tween wall sleeve and wall will be at or near the minimum clear-
ance distance, mount these kits on the sleeve before installing
the sleeve in the wall. The kit installation instructions are in-
cluded with the accessory kits.
Dimension "B"
in Table 1
17