Maytag Amana PTC A Series Service Instructions Manual page 12

Package terminal, air conditioners & heat pumps
Table of Contents

Advertisement

SPECIFICATIONS
1, 7 , 9 , 10 , 12
Model
1 , 3, 1 1
Voltage
Capacity (BUTH)
Amps
Watts
EER
UNIT WITHOUT
ELECTRIC HEATER
2 , 4 , 12
Minimum Circuit Ampacity
CFM
HIGH
LOW
HIGH
LOW
FAN ONLY*
COMPRESSOR & FAN*
Dehumidification
(pints/hr)
Net Weight
Shipping Weight
(approx. lbs.)
COOLING DATA (COOLING with ELECTRIC HEAT)
1, 7 , 9 , 10 , 12
Model
1 , 3, 11
Voltage
Capacity (BUTH)
Amps
Watts
EER
UNIT WITHOUT
ELECTRIC HEATER
2, 4 , 12
Minimum Circuit Ampacity
CFM
HIGH
LOW
HIGH
LOW
FAN ONLY*
COMPRESSOR & FAN*
Dehumidification
(pints/hr)
Net Weight
Shipping Weight
(approx. lbs.)
12
COOLING DATA (COOLING with ELECTRIC HEAT)
PTC
PTC
073D**AR
093D**AR
230 / 208
230 / 208
7,200/7,000
9,100 / 8,900
3.5/3.5
4.4/4.4
625/600
790 / 775
11.5/11.7
11.5
4.2
5.4
220/215
220/215
195/190
195/190
240/235
240/235
210/205
210/205
65*
65*
65*
65*
1.6
2.6
90
95
105
110
PTC
PTC
094D****
124C**AM
265
265
9100
11,600
3.6
4.7
790
1,055
11.5
11.0
4.4
5.8
Cool, Wet Coil
220
225
195
200
Dry Coil
240
230
210
200
Ventilated Air
65*
65*
65*
65*
2.6
3.3
95
105
110
120
PTC
PTC
123C**AM
123D**AR
230 / 208
230 / 208
11,700 / 11,600 12,000 / 11,800 13,300 / 13,200
4.8/5.2
5.4/5.4
1,070,/,1,040
1,120,/,1,100
11.0/11.2
10.7
6.4
6.6
Cool, Wet Coil
220/215
310/300
195/190
240/230
Dry Coil
240/235
335/325
210/205
260/250
Ventilated Air
65*
70*
65*
70*
3.3
3.3
105
105
120
120
* Approximately 95 CFM with optional power vent kit. Actual vent
CFM performance will vary due to application and installation
conditions.
PTC
154D****
NOTES:
265
1. All 265V models must use Amana
brand hard wire kit (PTPWHWK4).
14000
2. Minimum circuit ampacity ratings conform to the National Electric Code.
However, local codes should apply. Minimum voltage on 230/208 volt models is
6.1
197 volts; maximum is 253 volts.
3. Minimum voltage on 265 volt models is 238.5 volts; maximum is 291.5 volts.
1458
4. Overcurrent protection for all units without electric heaters is 15 amps.
Overcurrent protection on 265 volt models must be cartridge-style time delay
9.6
fuses (included and factory installed on Amana
See heater performance for total MCA.
5. Heating capacity and efficiency are based on unit operation without condensate
7.5
pump. Unit automatically switches to electric heat at approximately 24°F
outdoor ambient.
6. Total watts for 12,000 and 15,000 Btuh models. Subtract 70 watts for PT07/09
7. Please specify 2-digit heater kW size to complete model serial number.
8. Total amps for 12,000 and 15,000 Btuh models; subtract 0.2 amps for PT07/09
210
9. Refrigerant used in all systems is R-22.
10. All units meet or exceed ASHRAE 90.1 standards..
240
11. All units less than 250 volts have a Leak Current Detector Interrupter (LCDI)
power cord and meeat UL 484 standards.
12. Refer to electric heat performance data for total MCA and recommended
overcurrent protection. Amps and Watts notation refers to compressor models
335
only.
260
70
70
4.4
110
125
PTC****A*
PTC
PTC
133D**AR
153D**AR
230 / 208
230 / 208
14,000/13,800
5.9/6.4
6.7/6.7
1265/1235
1445/1420
10.5/10.7
9.7
7.8
8.2
310/300
310/300
240/230
240/230
335/325
335/325
260/250
260/250
70*
70*
70*
70*
3.3
4.4
105
110
120
125
®
brand's subbase (PTSB4**E) or an Amana
®
brand all 265 volt chassis).
®