    Content Safety guidelines ____________________3 Description of the device ______________4 Explanation of symbols _______________5 Technical data _____________________5 Operation ________________________6 Operation mode selection______________6 Intensity adjustment _________________6 Operation errors ____________________7 Battery care _______________________8 Resetting, modifications and repairs ______9 Warranty _________________________9 Maintenance and cleaning _____________9 Scope of supply_____________________9...
  • Page 3: Safety Guidelines

    (not less than 10°C or more than 40°C or a relative humidity of more than 90%). • Do not use the SchnarchSTOP if it is not working properly or if it has been damaged in any way.
  • Page 4: Description Of The Device

    CAUTION! If using a both a SchnarchSTOP device and another high frequency medical device concur- rently, burning under the electrodes may occur. Operation in the vicinity (e. g. 1 meter) of a short- wave or microwave device may cause fluctuati- ons in the output values of the device.
  • Page 5: Explanation Of Symbols

    Explanation of symbols Read the operating instructions carefully before use! Type BF application This product is in accordance with the directive 93/42/EEC for medical products of June 14, 0197 1993. Item respectively order number of the manufacturer Year of construction of the device Output power of the device Power supply of the device Technical data...
  • Page 6: Operation

    Operation Before using the SchnarchSTOP, the battery needs to be connected (see paragraph “battery ca- re”). Afterwards, the electrodes must be connec- ted to the device and placed appropriately. Therefore, connect the electrodes to the cables and then, insert the double plug securely into the SchnarchSTOP device outlet (4).
  • Page 7: Operation Errors

    Operation errors The SchnarchSTOP steadily controls settings and connection of the electrodes. When an ope- ration error is detected, the pulse LED and the operation mode LED will flash alternately. For all operation errors applies: Remove the er- ror by turning the intensity knob back in direc- tion to 0.
  • Page 8: Battery Care

    direction to 0 until the pulse LED goes off (do not switch off the device). 4. Changing the operation mode during stimulation When actuating the operation mode selector switch during stimulation, an operation error as described under point 1 will be shown. However, no pulses will be produced.
  • Page 9: Resetting, Modifications And Repairs

    SchnarchSTOP provided that resetting, modifications, and re- pairs are carried out by persons authorized by him, and that the SchnarchSTOP is used in ac- cordance with the operating instructions. Warranty During the warranty period of one year from the...
  • Page 12 0197 Manufacturer: Pierenkemper GmbH Hörnsheimer Eck 19 · D-35578 Wetzlar www.pieren-tech.de 451600-0202 Version 1...