Download Print this page
jablotron JA-163A Manual

jablotron JA-163A Manual

Rb wireless outdoor battery-powered siren

Advertisement

Quick Links

JA-163A RB Wireless outdoor battery-powered siren
The JA-163A RB is a component of the JABLOTRON 100 system.
It is used for system alarm indication outside a building. It can also be used
for supplementary acoustic signalling (PG activation, arming, chirps).
The siren is powered by just one lithium battery with no other external
power. The JA-163A RB includes only the base with the JA-163A-BASE-
RB PCB, the BAT-100A lithium battery and always has to be completed
with a cover from the JA-1X1A-C-xx series (see following table). The siren
occupies one position in the system. The product should be installed by
a trained technician with a valid certificate issued by an authorized
distributor.
For combinations of colour and cover material, see the following table:
Cover type
Colour and cover
material
JA-1X1A-C-GR
Grey plastic
JA-1X1A-C-ST
Stainless steel sheet
JA-1X1A-C-WH
White plastic
JA-1X1A-C-GR-B
Grey plastic
JA-1X1A-C-ST-B
Stainless steel sheet
JA-1X1A-C-WH-B
White plastic
Installation
The whole enrolment procedure has to be done in service mode
of the control panel. There must be a JA-11xR radio module installed
in the control panel.
Figure 1: 1 – hole for installing; 2 – piezo sounders; 3 – BAT-100 lithium battery
with reusable battery strap (up to 2 batteries can be used); 4 – PCB;
5 – spirit level; 6 – hole for installation with tamper detection; 7 – front cover
screw; 8 – string with clip connecting the front cover for easy installation
The siren should be installed on a vertical
wall,
with
the
Avoid installing the siren near the gutters and
on other places where there is a danger of ice
accumulation.
1.
Attach the siren onto a suitable place using 2 screws through
the holes (1) and (6). The spirit level can be used for easy
installation (5).
2.
Connect the BAT-100A lithium battery (3) to the connector (11).
3.
Proceed according to the control panel installation manual.
Basic procedure:
a.
When the battery is connected, the yellow LED (12) indicates
by a permanent light that the siren has not been enrolled into
the system yet.
b. Go to the F-Link software, select the required position
in the Devices tab and launch the enrolment mode by clicking on
the Enroll option.
c.
Press the button marked LEARN (10) – the siren is thus enrolled
and the yellow LED indicator goes off.
4.
Put back the siren cover and attach it using the screw (7).
5.
Perform siren properties setting, see the following chapter: Internal
settings of the siren.
JA-163A RB Wireless outdoor battery-powered siren
Strobe colour
Red
blue
flasher
facing
downwards.
Notes:
The siren can also be enrolled into the system by entering
its production code (9) in the F-Link software. You can find
the production code on the sticker, glued on the PCB.
All numbers under the bar code shall be entered (1400-00-0000-
0001).
The siren can be powered by up to two BAT-100A batteries and we
recommend this when longer siren operation time is required.
There is a place prepared for second battery use see Figure 1.
Connect the battery to the other connector (11). The battery connection
order doesn´t matter.
Figure 2: 9 – production code; 10 – LEARN (enrollment) button;
11 – battery connector; 12 – yellow fault indicator; 13 – mini USB connector;
14 - piezo siren connection (attention: high voltage);
15 – external antenna connector; 16 - high intensity red LED flashers
Erasing the siren from system / RESET
Use this procedure when the siren has to be erased from one system
and enrolled to another one. Proceed this way:
1. The control panel has to be in Service mode.
2. Open the siren cover and disconnect the BAT-100A battery from
its connector.
3. Go to the F-Link software, „Devices" tab, and erase the siren from
the control panel and leave service mode.
4. Connect the BAT-100A battery. Then press and hold the LEARN
button (10) for approximately 8 sec until the yellow LED (12) starts
flashing. Then release the button.
5. When flashing expires (2 x 7 flashes) the yellow LED illuminates.
This indicates that the siren is not enrolled.
Notes:
-
When a reset is done the yellow LED goes off and it means that
there is some control panel in the siren's radio range with
an open service mode and the enrollment procedure has been
performed again and the siren is assigned to that control panel.
1.
A FW update can be performed by the F-Link software in service
mode, but only by a user with Service authorisation.
2.
Start the F-Link software and enter service mode.
3. Open the siren cover.
4. Do not disconnect the battery!
5. Connect a PC to the siren using a mini USB cable.
6. FW update mode is indicated by the flickering of the yellow LED.
7. Continue as with updating the control panel using F-Link software;
F-
select the USB option (typically at the first position).
8. Press the OK button to perform an update of the selected device.
9. Disconnect the mini USB cable.
10. Close the siren cover.
11. Check the siren settings via F-Link SW, Devices / Internal
settings.
12.
Test the siren functions.
Notes:
A mini USB cable is not in the supplied accessories of the siren, control
panel or any other device. You can use the cable from
the JA-190T card reader. We strongly recommend connecting
the USB cable straight to the PC connection as using a USB HUB can
reduce the reliability.
According to the changes which have been done during the update,
previous settings might stay or settings could be erased to default.
When a reset has been done you can reload the previous settings
by the Import button and restore them with no negative influence
on the new firmware.
Internal settings of the siren
The siren properties can be set in the Devices window of the F-Link
software. When at the siren position, use the Internal settings option
1 / 2
FW update
. In the device options
MNM51103

Advertisement

loading

Summary of Contents for jablotron JA-163A

  • Page 1 JA-163A RB Wireless outdoor battery-powered siren The JA-163A RB is a component of the JABLOTRON 100 system. Notes: It is used for system alarm indication outside a building. It can also be used The siren can also be enrolled into the system by entering for supplementary acoustic signalling (PG activation, arming, chirps).
  • Page 2: External Antenna Use

    Technical specifications the whole exit time when the system is fully set – intermittent beeping. The JA-163A RB parts (lithium battery, front cover and base) are Upon loss communication: YES / NO - When enabled, the siren supplied individually. The reason is the free selection of a wide range sounds in case of loss communication with the control panel longer than of a front covers and the transportation of lithium batteries.