Motion Detector Installation - jablotron Azor User Manual

Gsm mini alarm
Hide thumbs Also See for Azor:
Table of Contents

Advertisement

Motion detector installation

− The detector should be installed in the corner (facing the room), 2 to 2.5m above
the floor. The detector is able to cover an area of up to 10 x 10m*.
− The detector holder should be fixed so that the sensor window points diagonally into
the room (the arrow in the holder should point upwards).
− Remove the transportation cap from the tamper contact.
− Open the detector cover (by pressing the sides along the window).
− Connect the batteries (leave the internal switches in the 1 STANDARD and 2 DELAY
positions).
− Close the detector and push it on to the holder.
− Wait until the indicator light turns off (calibration is completed) and test whether
the detector reacts to human movement.
− Detected motion is indicated with flashing. You can test for 5 minutes and then
the indicator light turns off. You can repeat the test by opening and closing the detector
housing.
Tips and specifications
*) The detector must have an unrestricted view of the room. To avoid false alarms:
The detector must not be located opposite radiators or other sources of heat with curtains
hanging above them.
It should not be aimed at the windows.
It must not be located near open windows, doors or ventilators (it can react to draughts).
There must not be any things or animals with a temperature around 36 °C (pets, rodents, warm
air from electric appliances, radiator grilles, etc.) in the guarded area.
MLO51206
- 8 -

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents