All manuals and user guides at all-guides.com Owners & Installation Freestanding Gas Stove Models: FG39-NG FG39-LPG PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Your unit should be serviced annually by an authorised service person.
Page 2
All manuals and user guides at all-guides.com To the New Owner: Congratulations! You are the owner of a state-of-the-art Regency Room Sealed Gas Stove by FPI Fireplace Products International Ltd. The Regency Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove.
All manuals and user guides at all-guides.com TABLE OF CONTENTS Page Page Safety Label Operating Instructions Operating Instructions ..........23 Safety Label ............4 Lighting Instructions ..........23 Resetting the Unit ..........23 Installation Shutdown Instructions ..........23 First Fire ..............23 Specifications ............
All manuals and user guides at all-guides.com INSTALLATION IMPORTANT: SAVE THESE INSTRUCTIONS Note: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or prop- erty damage. Failure to follow these instructions may also void your fire insurance and/or war- ranty.
All manuals and user guides at all-guides.com INSTALLATION FG39-NG & FG39-LPG Reference Dimensions CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibil- ity of the manufacturer. CLEARANCES TO COMBUSTIBLES The farthest distance is correct if the two clearances do not coincide.
All manuals and user guides at all-guides.com INSTALLATION INSTALLATION FLUEING LOUVER PRECAUTIONS INSTALLATION INTRODUCTION Attach the top & bottom louvres to the side stove panel using 2 screws per side. Note: These flue pipes must not be con- nected to any other appliance. IMPORTANT The gas appliance and flue system must be flueed directly to the outside of the...
All manuals and user guides at all-guides.com INSTALLATION FLUEING ARRANGEMENTS The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontal terminations. Maximum one 90 elbow (two 45 elbows equal one 90 elbow). The shaded area in the diagram below shows all allowable combinations of straight vertical and offset to vertical runs with vertical terminations.
All manuals and user guides at all-guides.com INSTALLATION DV STOVE HORIZONTAL FLUE KIT Qty. Description AstroCap Optional: AstroCap Note: a ) Liner sections should be continuous without any joints or seams. b) This is an approved system, therefore components in this system must not be substituted for any other manufactur- er's products.
Page 11
All manuals and user guides at all-guides.com INSTALLATION Crimped section of rigid pipe seats into the 90 elbow. Only cut the un- crimped side of pipe. #8 x ½" (13mm) Self Tapping, Stainless Steel #8 x ½" (13mm) Self Tapping, Black #8 x 1½"...
All manuals and user guides at all-guides.com INSTALLATION DURA-FLUE Note: These are the minimum pieces required. Other parts may be re- TERMINATION KIT quired for your particular instal- lation. See below for a list of flue parts. Part # Description Minimum components for a Dura-Flue Horizontal Installation: Minimum components for a Dura-Flue...
All manuals and user guides at all-guides.com INSTALLATION Hint: Apply silicone to female end. arrow on the flue cap should be point- ing up. Parts not supplied by Dura-Flue DURA-FLUE HORIZONTAL INSTALLATIONS Diagram 1 Diagram 5 Note: Diagram 2 Note: Regency FG39 FireGenie Freestanding Gas Stove...
All manuals and user guides at all-guides.com INSTALLATION Note: If an offset is necessary in the attic to avoid obstructions, it is impor- tant to support the flue pipe every 3 feet, to avoid excessive stress on the elbows, and possible sep- aration.
All manuals and user guides at all-guides.com INSTALLATION CATHEDRAL CEILINGS Notes: Round Support (RDS) & Square Support (SQS) nails Ceiling Firestop 1-1/4" (32mm) Min. 1-1/4" (32mm) Min. Slope "X" 1-1/4" (32mm) Min. 0/12 - 2/12 4" (102mm) 2/12 - 7/12 5-1/2"...
All manuals and user guides at all-guides.com INSTALLATION GAS CONNECTION Max. Input GAS PIPE PRESSURE Min. Input TESTING Supply Pressure Manifold Pressure Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve. AERATION Max.
All manuals and user guides at all-guides.com INSTALLATION Conversion Kit for NG to LPG Model #736-969 Antenna Control Box Cover Pilot Pilot Pilot Orifice Assembly Extrusion Tube Jumper Location Jumper Burner Orifice Pilot Tube Regency FG39 FireGenie Freestanding Gas Stove...
Page 18
All manuals and user guides at all-guides.com INSTALLATION Adjusting the Outlet Pressure Maximum pressure: NOTE: Minimum pressure: NOTE: Cable Electric Modulator WARNING: Regency FG39 FireGenie Freestanding Gas Stove...
All manuals and user guides at all-guides.com INSTALLATION CONVERSION TO LOWER BTU RATING LOG SET INSTALLATION THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are NG Conversion Kit 730-920...
Page 20
All manuals and user guides at all-guides.com INSTALLATION G)02-48 A)02-65 A)02-65 A)02-65 D)02-46 B)02-56 E)02-45 C)02-44 Pins on Rear Log Support Notch Cutout G)02-48 E)02-45 B)02-56 E)02-45 Side View Bracket The bottom right edge of Log G)02-48 must B)02-56 sit snugly against the bracket A)02-65 lava rock B)02-56...
All manuals and user guides at all-guides.com INSTALLATION FRONT DOOR FINAL CHECK INSTALLATION Note: The door latch may require ad- justment as the door gasket ma- terial compresses after a few fires and after glass replacement. Turn the latch catch inward or out- ward to loosen or tighten.
All manuals and user guides at all-guides.com OPERATING INSTRUCTIONS OPERATING RESETTING FAN OPERATION THE UNIT INSTRUCTIONS SHUTDOWN Control Panel INSTRUCTIONS LIGHTING FIRST FIRE INSTRUCTIONS FIRST FIRE ADJUSTING FLAME HEIGHT NOTE: NOTE: Regency FG39 FireGenie Freestanding Gas Stove...
All manuals and user guides at all-guides.com OPERATING INSTRUCTIONS SUMMARY OF NORMAL OPERATING PILOT ADJUSTMENT CONTROLS SOUNDS OF GAS APPLIANCES On/Off Button nor- mal operating sounds NOTE: If you have an incorrect flame Flame: pattern, contact your Regency dealer for Increase - further instructions.
All manuals and user guides at all-guides.com OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS A ) BEFORE LIGHTING smell all around the appliance B) Do not use this appliance if any part has been area for gas. Be sure to smell next to the floor under water.
All manuals and user guides at all-guides.com MAINTENANCE MAINTENANCE GOLD-PLATED DOORS INSTRUCTIONS void the warranty. Regency FG39 FireGenie Freestanding Gas Stove...
All manuals and user guides at all-guides.com MAINTENANCE LOG REPLACEMENT Removing Glass: Do not remove the nuts underneath the retainers. Note: Improper positioning of logs may create carbon build-up and will al- ter the units performance which is not covered under warranty. The glass must have gasketing around it.
All manuals and user guides at all-guides.com MAINTENANCE Hint for pushing fan down onto pins - rub a bit of dish soap on the grommet so it will slide more easily onto the pin. Check to make sure the fan is seated properly on the pins - try to move the fan back and forth, there should be no noise, if there is check that the grommets haven't...
All manuals and user guides at all-guides.com MAINTENANCE REMOVING VALVE TRAY NOTE: Always shut off the gas and dis- connect the power supply before removing the valve. Ground 5 Pin Wire Molex Connector Manual Switch Reset Cables Cable Regency FG39 FireGenie Freestanding Gas Stove...
All manuals and user guides at all-guides.com PARTS LIST ELECTRONIC COMPONENTS PARTS LIST 910-915 910-082 910-089 910-088 910-912 910-084 910-526 910-080 910-906 910-083 910-514 910-521, 910-522, 910-523 910-916 Fan Resistor Intermittent Pilot Direct Spark Ignitor Flame Cable Spark Cable Control Box Manual Control Valve Control Box Cable...
All manuals and user guides at all-guides.com PARTS LIST FG39 MAIN ASSEMBLY Part # Description Part # Description Part# Description Regency FG39 FireGenie Freestanding Gas Stove...
Page 32
All manuals and user guides at all-guides.com PARTS LIST FG39 BURNER & LOG ASSEMBLY Part # Description Regency FG39 FireGenie Freestanding Gas Stove...
Page 33
All manuals and user guides at all-guides.com PARTS LIST FG39 DOOR ASSEMBLIES Part # Description Regency FG39 FireGenie Freestanding Gas Stove...
All manuals and user guides at all-guides.com WARRANTY This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim. It does not cover installation and operational related problems such as over- firing, downdrafts or spillage caused by environmental con- ditions, nearby trees, buildings, hilltops, mountains, inade- quate flueing or ventilation, excessive offsets, negative air pressures caused by insufficient make up air, mechanical...
Page 36
All manuals and user guides at all-guides.com...
Need help?
Do you have a question about the FireGenie FG39-LPG and is the answer not in the manual?
Questions and answers