Regency Fireplace Products FireGenie FG39-LPG Owners & Installation

Freestanding gas stove
Table of Contents

Advertisement

Quick Links

Owners &
Installation
Your unit should be serviced
annually by an authorised service
person.
All manuals and user guides at all-guides.com
Freestanding Gas Stove
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Models: FG39-NG
FG39-LPG

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FireGenie FG39-LPG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Regency Fireplace Products FireGenie FG39-LPG

  • Page 1 All manuals and user guides at all-guides.com Owners & Installation Freestanding Gas Stove Models: FG39-NG FG39-LPG PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Your unit should be serviced annually by an authorised service person.
  • Page 2 All manuals and user guides at all-guides.com To the New Owner: Congratulations! You are the owner of a state-of-the-art Regency Room Sealed Gas Stove by FPI Fireplace Products International Ltd. The Regency Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove.
  • Page 3: Table Of Contents

    All manuals and user guides at all-guides.com TABLE OF CONTENTS Page Page Safety Label Operating Instructions Operating Instructions ..........23 Safety Label ............4 Lighting Instructions ..........23 Resetting the Unit ..........23 Installation Shutdown Instructions ..........23 First Fire ..............23 Specifications ............
  • Page 4: Safety Label

    All manuals and user guides at all-guides.com SAFETY LABEL NOTE: (Australia Only) Regency FG39 FireGenie Freestanding Gas Stove...
  • Page 5: Installation

    All manuals and user guides at all-guides.com INSTALLATION IMPORTANT: SAVE THESE INSTRUCTIONS Note: Failure to follow the instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or prop- erty damage. Failure to follow these instructions may also void your fire insurance and/or war- ranty.
  • Page 6: Installation Checklist

    All manuals and user guides at all-guides.com INSTALLATION FG39-NG & FG39-LPG Reference Dimensions CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibil- ity of the manufacturer. CLEARANCES TO COMBUSTIBLES The farthest distance is correct if the two clearances do not coincide.
  • Page 7: Louver Installation

    All manuals and user guides at all-guides.com INSTALLATION INSTALLATION FLUEING LOUVER PRECAUTIONS INSTALLATION INTRODUCTION Attach the top & bottom louvres to the side stove panel using 2 screws per side. Note: These flue pipes must not be con- nected to any other appliance. IMPORTANT The gas appliance and flue system must be flueed directly to the outside of the...
  • Page 8: Exterior Flue Termination Locations

    All manuals and user guides at all-guides.com INSTALLATION EXTERIOR FLUE TERMINATION LOCATIONS Regency FG39 FireGenie Freestanding Gas Stove...
  • Page 9: Flueing Arrangements - Horizontal

    All manuals and user guides at all-guides.com INSTALLATION FLUEING ARRANGEMENTS The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontal terminations. Maximum one 90 elbow (two 45 elbows equal one 90 elbow). The shaded area in the diagram below shows all allowable combinations of straight vertical and offset to vertical runs with vertical terminations.
  • Page 10: Dv Stove Horizontal Flue Kit

    All manuals and user guides at all-guides.com INSTALLATION DV STOVE HORIZONTAL FLUE KIT Qty. Description AstroCap Optional: AstroCap Note: a ) Liner sections should be continuous without any joints or seams. b) This is an approved system, therefore components in this system must not be substituted for any other manufactur- er's products.
  • Page 11 All manuals and user guides at all-guides.com INSTALLATION Crimped section of rigid pipe seats into the 90 elbow. Only cut the un- crimped side of pipe. #8 x ½" (13mm) Self Tapping, Stainless Steel #8 x ½" (13mm) Self Tapping, Black #8 x 1½"...
  • Page 12: Dura-Flue Termination Kit

    All manuals and user guides at all-guides.com INSTALLATION DURA-FLUE Note: These are the minimum pieces required. Other parts may be re- TERMINATION KIT quired for your particular instal- lation. See below for a list of flue parts. Part # Description Minimum components for a Dura-Flue Horizontal Installation: Minimum components for a Dura-Flue...
  • Page 13: Dura-Flue Horizontal Installation

    All manuals and user guides at all-guides.com INSTALLATION Hint: Apply silicone to female end. arrow on the flue cap should be point- ing up. Parts not supplied by Dura-Flue DURA-FLUE HORIZONTAL INSTALLATIONS Diagram 1 Diagram 5 Note: Diagram 2 Note: Regency FG39 FireGenie Freestanding Gas Stove...
  • Page 14: Dura-Flue Vertical Termination Installation

    All manuals and user guides at all-guides.com INSTALLATION Note: If an offset is necessary in the attic to avoid obstructions, it is impor- tant to support the flue pipe every 3 feet, to avoid excessive stress on the elbows, and possible sep- aration.
  • Page 15: Offset Chart

    All manuals and user guides at all-guides.com INSTALLATION CATHEDRAL CEILINGS Notes: Round Support (RDS) & Square Support (SQS) nails Ceiling Firestop 1-1/4" (32mm) Min. 1-1/4" (32mm) Min. Slope "X" 1-1/4" (32mm) Min. 0/12 - 2/12 4" (102mm) 2/12 - 7/12 5-1/2"...
  • Page 16: Gas Connection

    All manuals and user guides at all-guides.com INSTALLATION GAS CONNECTION Max. Input GAS PIPE PRESSURE Min. Input TESTING Supply Pressure Manifold Pressure Note: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve. AERATION Max.
  • Page 17: Conversion From Ng To Lpg

    All manuals and user guides at all-guides.com INSTALLATION Conversion Kit for NG to LPG Model #736-969 Antenna Control Box Cover Pilot Pilot Pilot Orifice Assembly Extrusion Tube Jumper Location Jumper Burner Orifice Pilot Tube Regency FG39 FireGenie Freestanding Gas Stove...
  • Page 18 All manuals and user guides at all-guides.com INSTALLATION Adjusting the Outlet Pressure Maximum pressure: NOTE: Minimum pressure: NOTE: Cable Electric Modulator WARNING: Regency FG39 FireGenie Freestanding Gas Stove...
  • Page 19: Conversion To Lower Btu Rating

    All manuals and user guides at all-guides.com INSTALLATION CONVERSION TO LOWER BTU RATING LOG SET INSTALLATION THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are NG Conversion Kit 730-920...
  • Page 20 All manuals and user guides at all-guides.com INSTALLATION G)02-48 A)02-65 A)02-65 A)02-65 D)02-46 B)02-56 E)02-45 C)02-44 Pins on Rear Log Support Notch Cutout G)02-48 E)02-45 B)02-56 E)02-45 Side View Bracket The bottom right edge of Log G)02-48 must B)02-56 sit snugly against the bracket A)02-65 lava rock B)02-56...
  • Page 21: Front Door Installation

    All manuals and user guides at all-guides.com INSTALLATION FRONT DOOR FINAL CHECK INSTALLATION Note: The door latch may require ad- justment as the door gasket ma- terial compresses after a few fires and after glass replacement. Turn the latch catch inward or out- ward to loosen or tighten.
  • Page 22: Wiring Diagram

    All manuals and user guides at all-guides.com INSTALLATION WIRING Regency FG39 FireGenie Freestanding Gas Stove...
  • Page 23: Operating Instructions

    All manuals and user guides at all-guides.com OPERATING INSTRUCTIONS OPERATING RESETTING FAN OPERATION THE UNIT INSTRUCTIONS SHUTDOWN Control Panel INSTRUCTIONS LIGHTING FIRST FIRE INSTRUCTIONS FIRST FIRE ADJUSTING FLAME HEIGHT NOTE: NOTE: Regency FG39 FireGenie Freestanding Gas Stove...
  • Page 24: Summary Of Controls

    All manuals and user guides at all-guides.com OPERATING INSTRUCTIONS SUMMARY OF NORMAL OPERATING PILOT ADJUSTMENT CONTROLS SOUNDS OF GAS APPLIANCES On/Off Button nor- mal operating sounds NOTE: If you have an incorrect flame Flame: pattern, contact your Regency dealer for Increase - further instructions.
  • Page 25: Copy Of The Lighting Plate Instructions

    All manuals and user guides at all-guides.com OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS A ) BEFORE LIGHTING smell all around the appliance B) Do not use this appliance if any part has been area for gas. Be sure to smell next to the floor under water.
  • Page 26: Maintenance

    All manuals and user guides at all-guides.com MAINTENANCE MAINTENANCE GOLD-PLATED DOORS INSTRUCTIONS void the warranty. Regency FG39 FireGenie Freestanding Gas Stove...
  • Page 27: Log Replacement

    All manuals and user guides at all-guides.com MAINTENANCE LOG REPLACEMENT Removing Glass: Do not remove the nuts underneath the retainers. Note: Improper positioning of logs may create carbon build-up and will al- ter the unit’s performance which is not covered under warranty. The glass must have gasketing around it.
  • Page 28: Fan Maintenance

    All manuals and user guides at all-guides.com MAINTENANCE Hint for pushing fan down onto pins - rub a bit of dish soap on the grommet so it will slide more easily onto the pin. Check to make sure the fan is seated properly on the pins - try to move the fan back and forth, there should be no noise, if there is check that the grommets haven't...
  • Page 29: Removing Valve Tray

    All manuals and user guides at all-guides.com MAINTENANCE REMOVING VALVE TRAY NOTE: Always shut off the gas and dis- connect the power supply before removing the valve. Ground 5 Pin Wire Molex Connector Manual Switch Reset Cables Cable Regency FG39 FireGenie Freestanding Gas Stove...
  • Page 30: Parts List

    All manuals and user guides at all-guides.com PARTS LIST ELECTRONIC COMPONENTS PARTS LIST 910-915 910-082 910-089 910-088 910-912 910-084 910-526 910-080 910-906 910-083 910-514 910-521, 910-522, 910-523 910-916 Fan Resistor Intermittent Pilot Direct Spark Ignitor Flame Cable Spark Cable Control Box Manual Control Valve Control Box Cable...
  • Page 31: Replacement Parts List

    All manuals and user guides at all-guides.com PARTS LIST FG39 MAIN ASSEMBLY Part # Description Part # Description Part# Description Regency FG39 FireGenie Freestanding Gas Stove...
  • Page 32 All manuals and user guides at all-guides.com PARTS LIST FG39 BURNER & LOG ASSEMBLY Part # Description Regency FG39 FireGenie Freestanding Gas Stove...
  • Page 33 All manuals and user guides at all-guides.com PARTS LIST FG39 DOOR ASSEMBLIES Part # Description Regency FG39 FireGenie Freestanding Gas Stove...
  • Page 34 All manuals and user guides at all-guides.com NOTES _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________...
  • Page 35: Warranty

    All manuals and user guides at all-guides.com WARRANTY This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim. It does not cover installation and operational related problems such as over- firing, downdrafts or spillage caused by environmental con- ditions, nearby trees, buildings, hilltops, mountains, inade- quate flueing or ventilation, excessive offsets, negative air pressures caused by insufficient make up air, mechanical...
  • Page 36 All manuals and user guides at all-guides.com...

This manual is also suitable for:

Firegenie fg39-ng

Table of Contents