03.99
Process data
softwiring of receive
Controlword 1
channel
connecting CBL controlword 1 (REF VALUE: PZD1) to converter controlword 1
1) use alternativly P555, P556 or P557 (AND function)
2) check P448 and P449 for JOG speed!
NOTE
After power-up till data transmission between PLC cpu and CBL the
alarm message A035 will occur and will be displayed (control bits 11
and 12 equals 0!). The duration depends on the converter type and the
configuration (tech board plugged?) and takes some seconds. After
starting data transmission via CC-Link to PLC cpu the alarm will be
automatically cleared.
Controlword 2
connecting CBL controlword 2 (REF VALUE: PZD4) to converter controlword 2
Siemens AG
6SE7087-6NX84-0GB0
SIMOVERT MASTERDRIVES
Parameter
Contents
P554
3100
1)
P555
3101
P565
3107
P568
3108
P569
3109
P571
3111
P572
3112
Parameter
Contents
P576
3400
P577
3401
P580
3404
P581
3405
P???
3411
P???
3412
P???
3413
Operating Instructions
Start-up of the CBL
Meaning
Mandatory: RUN/STOP
Mandatory: MRS function
Mandatory: reset error flag
2)
Mandatory: JOG mode
2)
Mandatory: JOG mode
Mandatory: STF (Forward)
Mandatory: STR (Reverse)
Meaning
Mandatory: RT function
Mandatory: RT function
Mandatory: RL, RM, RH
Mandatory: RL, RM, RH
Optional: Optionflag F27
Optional: Optionflag F28
Optional: Optionflag F29