Siemens Simovert Masterdrive FANC-SB Operating Instructions Manual page 64

Cbl communication board cc-link
Table of Contents

Advertisement

All manuals and user guides at all-guides.com
Diagnosis and troubleshooting
Case 10
ERRLED
Table 6-15
6-6
LED
Status
Flashing
CBL detects data communication errors (CRC
error) at data transmission!
Check:
Fault display during operation: CRC error at CC-Link
Operating Instructions
Diagnostic information CC-Link
Shield connection of the cable at housing of
CU and at all CC-Link stations (EMC
faults!)
Check cable length of CC-Link bus
according to the data transmission rate!