Advertisement

Repair

Air Cylinder Rebuild Instructions

1
1
Finger tighten all (4) bolts prior to wrench tightening. For wrench tightening,
turn each bolt 1/4 turn in a cross pattern until all (4) bolts are torqued to 350
in-lb (40 N•m).
2
Torque to 1200 in-lb (136 N•m).
3
Coat all sliding surfaces with lubricant, part 115982.
4
Apply sealant tape to npt fittings.
Prepare Machine for Kit Installation
1. Relieve pressure. See Pressure Relief Procedure,
page 33.
2. Shut down the machine. See Shutdown, page 34.
3. Disconnect the pressurized air input hose.
4. Loosen machine shield screws.
5. Remove the machine shield.
42
2
3
4
3
3
3
3
Disassemble the Air Cylinder
6. Remove the incoming power bracket from the
machine by removing the four attachment screws.
4