Data port

The data port(s) are implemented as Data Communications Equipment (DCE). The connectors
used are female 9-pin D-subs.
Signal name
Carrier detect, CD
Receive data, RXD
Transmit data, TXD
Data terminal ready, DTR
Signal ground, GND
Data set ready, DSR
Ready to send, RTS
Clear to send, CTS
Ring indicator, RI
226
Direction
Pin number
From DCE
From DCE
To DCE
From DCE
From DCE
To DCE
From DCE
From DCE
1
2
3
4
5
6
7
8
9