Figure 3-5. Vxibus Clk10 Routing - National Instruments MXI VXI-PCI8026 Getting Started

Ni-vxi/ni-visa software for linux
Table of Contents

Advertisement

Chapter 3
VXI-MXI-2 Configuration and Installation
From onboard oscillator
W3
From SMB (S3 must be set to "IN")
From MXIbus
a. CLK10 Generated from Onboard Oscillator (Default)
From onboard oscillator
W3
SMB CLK10 Direction
From SMB (S3 must be set to "IN")
From MXIbus
b. CLK10 Generated from SMB
From onboard oscillator
W3
From SMB (S3 must be set to "IN")
Receive CLK10 from MXIbus
From MXIbus
S7
c. CLK10 Generated from MXIbus

Figure 3-5. VXIbus CLK10 Routing

The VXI-MXI-2 can also be configured to drive the external CLK SMB
signal from the VXIbus CLK10 signal. Switch S3 controls whether the
VXI-MXI-2 drives or receives the external CLK SMB signal. If you change
the S3 setting to drive CLK10 out the external CLK10 SMB connector, do
not set the W3 jumper to receive the SMB CLK10 signal; instead use the
settings shown in either Figure 3-5a or Figure 3-5c as appropriate.
When switch S3 is set so that the VXI-MXI-2 receives the SMB CLK10
signal, you have the option to add a 50 is unused—its setting does not
matter—when S3 is configured to drive the external CLK SMB signal.
© National Instruments Corporation
3-9