Installation Details - Seeley Breezair EAS265 Installation Manual

Evaporative cooler
Table of Contents

Advertisement

Safety (cont)
Ensure that it is properly secured and upright as intended.
There is no need to adjust the water flow since the cooler is designed
to operate with maximum cooling at low air velocities.
Water pump replacement
:
Factory authorised pumps are fitted with thermal overload protection.
Water pumps may seize up and overheat, creating a fire risk. Pumps
that have thermal overload protection are designed to shut off the
pump if the motor overheats.
Factory authorised water pump
Seeley "Tornado" pump (part no. 095851)
"Power Clean" Style Timed Pumps
Under no circumstances are "Power Clean" style timed pumps to
be used in any Breezair air cooler.
non-approved device will cause serious damage to the special safety
circuits of this cooler.
Failure to follow this instruction will VOID ALL
WARRANTY and may create severe risk of electric shock and fire!
Fan Motor
This cooler is supplied with a fan motor made by the cooler
manufacturers. USE ONLY THE AUTHORISED FAN MOTOR
SUPPLIED.
Failure to follow this instruction will VOID ALL WARRANTY and
may create severe risk of electric shock and fire!
Factory Authorised Fan Motor
Seeley SEELECTRIC 2 speed motors:
½ HP MFD-2 motor part # 095431
¾ HP MFD-4 motor part # 095455
1.0 HP MFD-10 motor part # 095448
The fan motor is equipped with inbuilt overheating protection that
will reset automatically on cool-down to a safe temperature. This
may take up to 45 minutes.
2
Circuit Breaker Protection
This cooler is fitted with circuit breaker protection for the fan motor and
pump. Should the 2 speed fan motor overload, one of the circuit
breakers located on the front face of the junction box will trip, showing
a white button. To reset, press this white button until it "clicks" and
remains in.
TIP..... A tripped high speed circuit breaker usually shows that the
amp setting of the motor is too high.
3
Should the pump overload and the circuit breaker trip, the pump
should be examined carefully for electrical failure before resetting the
circuit breaker.
2
2
:
Use of these devices or any other
EA Evaporative Cooler
®
®

Installation details

Removing Pad Frames:
Each pad is clipped into the cooler cabinet and is removed by
using a medium sized screwdriver. (fig 4.)
Insert the screwdriver into 2 slots along the top edge of each side
of the pan and lever downwards. The pad frame will then slide
down and out of the cabinet.
4
Replacing Pad Frames
:
Ensure the pad frame is the correct way up by checking that the
ribbed gutter is at the top. Push the top edge of the frame under
the lip of the top panel. Then push the bottom edge into the edge
of the pan at the bottom. Two sharps hits by hand should locate it
over the clips. If this is not successful use the screwdriver to
lever the bottom edge of the pad frame over the clips.
Cooler Location
:
Check the proposed cooler location first, to ensure it is
structurally capable of supporting the weight of the cooler.
Polymer coolers are light-weight but they require adequate
support. The largest cooler in the EA range is about 250 lbs
(113Kgs).
Always locate the cooler where there is a plentiful supply of
clean fresh air, and not in a recess or close to the ground where
the air may be dusty or polluted.
SEE LATER SECTION "OPERATION OF COOLER" ABOUT
ADEQUATE EXHAUST OPENINGS REQUIRED.
Keep the cooler away from heater flues, exhaust vents
(especially kitchens) and sources of ignition. Avoid
dangerous situations.
Allow for adequate, SAFE, access around the cooler for
maintenance, especially for pad cleaning, water connections,
electrical connections, drain connections.
It is mandatory that water cannot enter the building as a result of
poor sealing (caulking or flashing) of the various penetrations
into the building (ducts, necks, water pipes, electrical conduits).
ILL725-A