Seeley Braemar SDHV 3Phase Series Owner's Manual

Seeley Braemar SDHV 3Phase Series Owner's Manual

Ducted inverter

Advertisement

Quick Links

OWNER'S MANUAL
DUCTED INVERTER
(English) (SDHV 3Phase SERIES)

Advertisement

Table of Contents
loading

Summary of Contents for Seeley Braemar SDHV 3Phase Series

  • Page 1 OWNER’S MANUAL DUCTED INVERTER (English) (SDHV 3Phase SERIES)
  • Page 2 IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is VERY IMPORTANT that you maintain your air conditioner and have it regularly serviced. Accordingly, it is a condition of warranty cover for your air conditioner that you comply with all of the maintenance and service requirements set out in this Manual.
  • Page 3: Table Of Contents

    WIRED CONTROLLER .................4 CONTROLLER LAYOUT................4 ON/OFF ......................5 MODE ......................5 TEMPERATURE, FAN SETTING ..............6 TIMER SETTING ..................6-7 CLOCK FUNCTION SETTING..............7 QUIET FUNCTION SETTING................7 LOCK FUNCTION ..................7 FILTER SETTING..................7 MAINTENANCE & SERVICE................8 MAINTENANCE SCHEDULE ................9 OPERATION TIPS.....................10 TROUBLESHOOTING ..................11 SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 4: Main Components

    MAIN COMPONENTS Signal wire INDOOR UNIT Gas-side connective pipe of system Liquid-side connective pipe of system OUTDOOR UNIT Indoor and Outdoor unit operating temperature range: Mode Indoor Unit Outdoor Unit Cooling -15°C to 48°C 16°C to 32°C Heating -15°C to 24°C 16°C to 27°C SDHV Series Ducted Inverter Unit...
  • Page 5: Introduction & Safety

    A return air filter MUST be installed by persons in order to avoid a hazard. the installer at the return air grille. The air filter should be inspected and cleaned at least every two weeks SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 6: Operation

    OPERATION Your Braemar Ducted Inverter Air Conditioning Unit has been designed and built with reliable, quality components. To ensure many years of trouble free, dependable service please read the following pages very carefully, and please ensure that you follow all of the instructions. WIRED CONTROLLER Please follow the below cautionary notes when using the wired controller:- 1.
  • Page 7: On/Off

    "Follow Me". This function changes the location of the temperature sensing point from the return air to the wired wall control. This function is canceled when is pressed again or when the system is switched off. Whilst activated, the following icon is displayed: SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 8: Temperature, Fan Setting

    OPERATION cont. Fan Speed Setting: Under COOL, Heat and/or FAN modes, press the fan speed button to adjust the fan speed setting. After each fan speed button press, the selector will circle as follows: AUTO - LOW - MEDIUM - HIGH NOTE: Under AUTO and DRY modes, the fan speed is not adjustable.
  • Page 9: Clock Function Setting

    After cleaning the filter, press for 3 seconds to reset the filter timer and the clean filter icon will not be displayed. SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 10: Maintenance & Service

    MAINTENANCE & SERVICE AIR FILTER with other debris that may build up over time, namely, leaves and the like. It is important to check and clean the air filter as per the Maintenance Schedule below. A dirty air filter will not REFRIGERANT allow the correct amount of clean air to pass through your air conditioner,...
  • Page 11: Maintenance Schedule

    Braemar Ducted Inverter Air Conditioning Unit as per the items and frequency set out in the Schedule, and as indicated elsewhere in this Manual. SEELEY INTERNATIONAL – OWNER’S MANUAL...
  • Page 12: Operation Tips

    OPERATION TIPS The following events may occur during normal operation: 1. Protection of the air conditioner. Compressor protection The compressor cannot restart for 3 minutes after it stops. • • The supply air drops below a pre-determined set point; this prevents the indoor coil from freezing.
  • Page 13: Troubleshooting

    NOTE: Seeley International strives for continuous product improvements, therefore specifications are subject to change without notice. Unit colour may vary slightly from that depicted in this booklet. Installation and commissioning of this system to the manufacturer's specification, and compliance with industry standards, and local, state and national regulatory codes, are the responsibility of the installer.
  • Page 16 It is the policy of Seeley International to introduce continuous product improvements. Accordingly, specifications are subject to change without notice. Please consult with your dealer to confirm the specifications of the model selected. Warranty Service Refrigerated Cooling 1300 526 477 seeleyinternational.com...