Safety Instructions; General Instructions - Seeley Breezair EAS265 Installation Manual

Evaporative cooler
Table of Contents

Advertisement

Safety

SAFETY INSTRUCTIONS

Important safety Instructions and Warnings
WARNING: The warnings and safety instructions in this manual
must be followed to reduce the risk of fire, electric shock or
injury, and to provide reasonable safety and efficiency in using
this Evaporative Air Cooler. The operator is responsible for
following the warnings and instructions in this manual and on the
cooler.
Read this entire manual before proceeding to install the
cooler.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their
safety.
Children should be supervised to ensure that they do not
play with the appliance.
Failure to observe these warnings and instructions will void
manufacturer's warranties and will discharge the
manufacturer of all liability.
CAUTION
!
ALWAYS disconnect the cooler from the power supply
before commencing maintenance procedures.
During maintenance procedures, NEVER use a naked flame for
any inspection or cleaning purpose as a fire could be caused by
a flame coming into contact with the cooler materials.
Avoid Dangerous Situations:
Protect the cooler from all sources of ignition because
polymers and cooling pads will burn.
NEVER use a water hose to squirt the interior of the cooler for
cleaning as residual water could damage electrical components
and create the risk of fire and /or electric shock to the user after
re-assembly.
In cases where BLEED-OFF is not used, pads will require
frequent inspection and replacement. Failure to do so may
cause water to leak into the building or onto the roof, that
may enter
electrical components and
create an electrical shock or fire hazard.
Where this condition is allowed to exist, the manufacturer
accepts no responsibility for any damage or injury that may
occur.
Installation, Repair and Operation
All installation and repair work must conform to local electrical,
!
water supply and environmental codes, rules and regulations
and applicable national standards.
All installation, maintenance and repair work must be done by
!
a licensed and qualified electrician and/or a qualified,
experienced heating, ventilating, air conditioning technician. All
such work must be effected with factory authorised spare parts
only.
Disconnect electrical power at the fuse or circuit breaker box
!
before installation commences. ALWAYS turn OFF the isolating
switch (disconnect) located on the junction box inside the cooler
BEFORE commencing any maintenance procedures. (Fig. 1).
Then disconnect the fan motor and pump plugs from the junction
box.
Use only the power supply voltage shown on the motor
!
nameplate.
Do not install or service the air cooler during rain, high wind or
!
severe weather conditions.
Keep loose hair, loose clothing, fingers and all other parts of the
!
body away from openings and moving parts. Check the cooler for
worn, loose, missing, or damaged parts before operation.
If you work with power tools, wear protective eyewear and gloves.
!
Take care when lifting or raising the air cooler to its final location.
!
Use safe equipment and never attempt to lift the cooler alone. Always
have assistance. Otherwise you might damage the cooler or the
building or injure yourself.
Ground Fault Circuit Interrupter (GFCI) protection should be
!
provided on the circuit supplying this air cooler. Receptacles are
available with built-in GFCI protection.
Air coolers installed on roofs must not have the waste water
!
directed onto the roof as stains will occur. Connect the cooler drain
outlet to a gutter or drain pipe using a suitable hose.
Always use the correct tools.
!
WARNING! the packaging plastic on this cooler can be a safety
!
hazard. Dispose of carefully.
Never drill holes in the pan or walls of the cooler. See details later
!
about where to drill holes for entry of services and cooler mounting.
Avoid dangerous situations. Do not use the cooler in the
!
presence of flammable liquids or gasses to avoid creating fire or
explosion. This air cooler is NOT flame retardant. A fire may
result from contact with a flame or from an electrical short.
Use of wrong replacement parts creates risk of severe electric
!
shock and fire which may result in serious property damage,
personal injury or death.
Secure all electrical connections inside junction box. Pump and fan
!
motor must plug into receptacles. Never splice outside junction box.
Failure to follow wiring instructions creates risk of severe electric
shock and fire.
ADDITIONAL SAFETY INSTRUCTIONS
Water pump
:
The water pump is supplied with this cooler and is factory fitted into its
correct location.
SEELEY INTERNATIONAL – INSTALLATION MANUAL
Keep children,
!
1
bystanders and animals
at a safe distance, a
minimum of 30ft (10m)
away from working
areas.
Dress safely. Wear
!
non-skid shoes when
working at high levels
and roofs. Do not wear
loose clothing or
personal accessories
while installing or
servicing the air cooler
as they may become
caught in moving parts.
1