PROBLEM
Pump runs but no water circulation.
Pump runs but pads lack water.
Continuous overflow of water.
Water being blown into the
building.
Unpleasant odour.
PROBABLE CAUSE
Insufficient water in pan.
Water hoses blocked.
Pump filter blocked.
Float valve adjustment not correct.
Heavy pad deposits.
Loose water hose connections.
Water hose broken.
Cover not fitted on float valve.
Pads not fitted correctly into pad
frames.
Water level too low, causing pump
to create fountain that is being
sucked into air stream.
Incorrect or damaged pads fitted.
New cooler pads.
Cooler located near source of
unpleasant odour.
Algae in pan water.
Pads remain wet after shut down.
Heavy pad deposits.
SEELEY INTERNATIONAL – INSTALLATION MANUAL
1
Troubleshooting
SUGGESTED REMEDY
Adjust float level.
Check and clean out blockage.
Unkink hose.
Clean pump filter and impellor
housing..
Adjust float valve. Ensure supply
water pipe is not straining the valve
sideways.
Clean or replace pads.
Tighten all connections.
Replace any cracked or broken
hoses.
Install correct cover on float valve
to prevent spray.
Make sure pads properly installed.
Increase water level.
Replace with manufacturer's
recommended pads.
Drain tank, refill, run pump for a
while.
Remove source of odour or
relocate cooler.
Drain pan, clean thoroughly with
strong cleansing agent, refill,
change pads.
Run fan on "vent" for 10 minutes
after cooling cycle to dry pads out.
Clean or replace pads.