Challenger Lifts 4P14EFX Installation, Operation & Maintenance Manual

Challenger Lifts 4P14EFX Installation, Operation & Maintenance Manual

Four post surface mounted lift

Advertisement

I
NSTALLATION
M
AINTENANCE
Surface Mounted Lift
Model 4P14EFX and 4P14XFX
200 Cabel Street, P.O. Box 3944 Louisville, Kentucky 40201-3944
Email:
sales@challengerlifts.com
Office 800-648-5438
IMPORTANT:
, O
Four Post
Closed Front
(14,000 lb Capacity)
Web site:
/
502-625-0700 Fax 502-587-1933
READ THIS MANUAL COMPLETELY BEFORE
INSTALLING or OPERATING LIFT
PERATION
M
ANUAL
www.challengerlifts.com
&
Rev 08/11/17

Advertisement

Table of Contents
loading

Summary of Contents for Challenger Lifts 4P14EFX

  • Page 1 & NSTALLATION PERATION AINTENANCE ANUAL Four Post Surface Mounted Lift Model 4P14EFX and 4P14XFX Closed Front (14,000 lb Capacity) 200 Cabel Street, P.O. Box 3944 Louisville, Kentucky 40201-3944 Email: Web site: sales@challengerlifts.com www.challengerlifts.com Office 800-648-5438 502-625-0700 Fax 502-587-1933 IMPORTANT: READ THIS MANUAL COMPLETELY BEFORE...
  • Page 2 Model 4P14 Flat Deck, Closed Front Installation, Operation and Maintenance ENERAL PECIFICATIONS : 4P14 [E X]FX ODEL LENGTH SPECIFICATIONS 4P14EFX 4P14XFX A Length Overall 20’ 5 ¾” 22’ 9 ¼” B Width Overall 10’ 10 ¾” C Inside Columns 116”...
  • Page 3 Model 4P14 Flat Deck, Closed Front Installation, Operation and Maintenance ERTICAL LEARANCE AFETY OTICES AND ECALS Check the height of the area where the lift is to be For your safety, and the safety of others, read and installed. Clearance should be calculated based on understand all of the safety notices and decals the full raised height of the lift.
  • Page 4 IDLER COLUMN ASS’Y shorted or damaged goods. Do this for your own protection. ENTRANCE RAMP WELD NOTIFY Challenger Lifts AT ONCE if any hidden CROSS BEAM ASS’Y loss or damage is discovered after receipt. POWER UNIT IT IS DIFFICULT TO COLLECT FOR LOSS OR...
  • Page 5 Model 4P14 Flat Deck, Closed Front Installation, Operation and Maintenance of the runway. Cable #1, #3, & #4 should be extending out from the rear of the power runway and cable #2 from the front of the power runway, Fig 4. 4) Position the front and rear cross beams, Fig 4.
  • Page 6 Model 4P14 Flat Deck, Closed Front Installation, Operation and Maintenance Fig 6 – Front Single-Stack (typical for idler and power runways) 13) Attach both cross beams to the runways (Fig. 4) with M12 x 35mm lg. flange head bolts (two at each end of each runway) being THREADED careful not to pinch the air line.
  • Page 7 Model 4P14 Flat Deck, Closed Front Installation, Operation and Maintenance 20) The anchor bolts must be installed at least 8” power runway near the power unit and attach from any crack, edge, or expansion joint. to the elbow fitting. 21) Use a concrete hammer drill with a 3/4 inch Do Not Use Teflon Tape or Pipe Dope on carbide bit.
  • Page 8 Model 4P14 Flat Deck, Closed Front Installation, Operation and Maintenance 31) B 37) Use the provided wire ties and adhesive tabs ERTAIN ITTINGS AND ONNECTIONS to connect the 4mm air line inside the ends of IGHT T IS THE INSTALLERS the front and rear cross beam to the side RESPONSIBILITY TO INSURE SYSTEM IS LEAK .
  • Page 9 Model 4P14 Flat Deck, Closed Front Installation, Operation and Maintenance ECAL LACEMENT 43) Clean the column surface before placing any decals. 44) Install safety decals ( NOTICE / CAUTION / ) at the power unit as shown in Fig WARNING 14 below.
  • Page 10 Model 4P14 Flat Deck, Closed Front Installation, Operation and Maintenance Wiring Diagram FOR SINGLE PHASE (Normally Open) FIELD CONNECTIONS FOR THREE PHASE FACTORY WIRED FOR 208−240V RECONNECTIONS FOR 440−480V Figure 16 Rev 08/11/17 4P14-X-IOM-A.doc...
  • Page 11 Challenger Lifts, Inc Owner/Employer shall maintain periodic inspection and maintenance records 200 Cabel Street recommended by the manufacturer or ANSI/ALI Louisville, KY.
  • Page 12 Model 4P14 Flat Deck, Closed Front Installation, Operation and Maintenance  If lift stops short of full rise or chatters, check Drive vehicle onto lift. Set parking brake and/or use wheel chocks that are provided with lift. fluid level and bleed both cylinders per Installation Instructions.
  • Page 13 Parts Breakdown Model 4P14EFX/4P14XFX IMPORTANT!!! Replace all worn, damaged, or broken parts with parts approved by Challenger Lifts Inc. or with parts meeting Challenger Lifts Inc. specifications. Contact your local Challenger Lifts Parts Distributor for pricing and availability. (Call Challenger Lifts Inc. (502) 625-0700 for the Parts Distributor in your area) Rev 08/11/17 4P14-X-IOM-A.doc...
  • Page 14 Model 4P14 Flat Deck, Closed Front Installation, Operation and Maintenance Parts Breakdown Fig A. General Layout Rev 08/11/17 4P14-X-IOM-A.doc...
  • Page 15 M20 HEX JAM NUT B40129 M20 HEX NUT Replace all worn, damaged, or broken parts with parts approved by Challenger Lifts Inc. or with parts meeting Challenger Lifts Inc. specifications. Contact your local Challenger Lifts Parts Distributor for pricing and availability.
  • Page 16 CABLE RETAINER WELD B44015 M27 JAM NUT Replace all worn, damaged, or broken parts with parts approved by Challenger Lifts Inc. or with parts meeting Challenger Lifts Inc. specifications. Contact your local Challenger Lifts Parts Distributor for pricing and availability.
  • Page 17 M8 x 16mm Lg HEX LOCKING FLANGE HEAD CAP SCREW B40438-R RUNWAY SHEAVE SPACER, 2 1/8” Replace all worn, damaged, or broken parts with parts approved by Challenger Lifts Inc. or with parts meeting Challenger Lifts Inc. specifications. Contact your local Challenger Lifts Parts Distributor for pricing and availability.
  • Page 18 ROLLER B40137 RETAINING RING Replace all worn, damaged, or broken parts with parts approved by Challenger Lifts Inc. or with parts meeting Challenger Lifts Inc. specifications. Contact your local Challenger Lifts Parts Distributor for pricing and availability. (Call Challenger Lifts Inc. (502) 625-0700 for the Parts Distributor in your area) Rev 08/11/17 4P14-X-IOM-A.doc...
  • Page 19 B40090 Button Valve Bracket Assembly (Contains items: 1, 2, 3, 4, 5, 6, 7, 8) Replace all worn, damaged, or broken parts with parts approved by Challenger Lifts Inc. or with parts meeting Challenger Lifts Inc. specifications. Contact your local Challenger Lifts Parts Distributor for pricing and availability.
  • Page 20 Model 4P14 Flat Deck, Closed Front Installation, Operation and Maintenance NOTES Rev 08/11/17 4P14-X-IOM-A.doc...

This manual is also suitable for:

4p14xfx4p14 series

Table of Contents