Specifications

Specifications are for units driving into an 8-ohm loads, (26 dB = 20
times voltage gain) and operating from 120 VAC, unless otherwise
specified.
"Standard 1 kHz Power" refers to maximum average power in watts at
1 kHz with 0.1% THD.
"Full Bandwidth Power" refers to maximum average power in watts
from 20 Hz to 20 kHz with 0.1% THD.
Performance
Input to Output Phase Delay: 0.4
Amplifier to Amplifier Phase Error: <0.1
Signal to Noise Ratio: At gain of 20, better than 105 dB (A-
weighted) below full output.
Total Harmonic Distortion (THD): <0.05% from 20 Hz to 1
kHz, increasing linearly to 0.1% at 10 kHz at full output.
Residual Noise (20Hz to 1kHz): <0.8mAmp.
Load Impedance: Rated for use into 2 ohms or less. Safe
with all types of loads, even reactive ones.
Required AC Mains: 60 Hz, 120VAC with 30A service.
Convertible to 100/ 200/208/230/240VAC at 50/60 Hz.
Maximum Current: 70Arms / 98A peak
Maximum Voltage: 120Vrms no load