Technical Data - Gira 5373 Series User Manual

Motion detector top unit system 3000
Table of Contents

Advertisement

System 3000
Motion detector top unit 1.10 m Standard, Motion detector top unit 2.20 m
Standard
4.2 Commissioning
Make settings
The adjusters for the brightness threshold and sensitivity are located on the rear of the motion
detector cover. The run-on time cannot be changed.
Setting the brightness threshold
Set the brightness threshold on the covers of the main device and all extensions. Different val-
ues can be set on the main device and extensions. There are 4 defined values for the bright-
ness threshold. In setting Ư, the motion detector operates independently of the brightness (day
operation). Setting ư for stairways according to DIN EN12464-1, 2003-3.
Turn adjuster (1).
Setting the sensitivity
Sensitivity can be set in 4 levels to minimize faulty switching.
Turn adjuster (2).
Testing the detection area
Make the test settings. For this, turn adjuster (1) to Test.
The motion detectors operates independently of the brightness and switches on for ap-
prox. 1 second when motion is detected. The sensitivity setting remains intact.
5

Technical data

Ambient temperature
Storage/transport temperature
32599602
10865947
Figure 10: Mount the cover at 90°
04.05.2018
-20 ... +45 °C
-25 ... +70 °C