Main Screen
The Main Screen is the default
screen for the control system at
sprayer startup. Pressing the #2 key switches between
PSI/gallon and MPa/liter units of measure. Press the #1 key
to scroll through the remaining menu screens.
For sprayers equipped with an eight-language
i
Digital ESC System:
Pressing the #2 key at the Main Screen switch-
es between MPa and Bar units of measure.
Pressing the #3 key at the Main Screen
changes the language of the text on the dis-
play. There are a total of eight languages
available. Each time the #3 key is pressed, a
different language will appear. The languages,
in order of appearance, are: English, Spanish,
French, German, Italian, Dutch, Swedish, and
Danish.
For sprayers purchased in Australia, the only
i
units of measure available are PSI/liter. Press-
ing the #2 key at the Main Screen will not
change the units of measure.
User Pre-Sets Screen
The User Pre-Sets screen
allows the user to set four
different pressure settings and save them for future use. To
select the User Pre-Sets screen, press the #4 key.
Press keys 1 through 4 from
the Select screen to select or
change a pre-set pressure.
Press the #4 key to select the
setting and the Main Screen
will appear.
Press the #2 key to change the
setting. On the following
screen, use the #2/+ key to
increase the setting or the #3/- screen to decrease the setting.
Once the desired setting has been reached, press the #4 key
to set and the Main Screen will appear. To select or change
the remaining three pre-sets, scroll to the User Pre-Sets screen
and repeat the above procedure.
Volume Pumped Screen
The Volume Pumped screen
shows the total number of
gallons or liters sprayed by the
sprayer.
To select the Volume Pumped
screen, press the #4 key.
Job Volume Screen
The Job Volume screen allows
the user to reset a gallon
counter to track usage on
specific jobs.
To select the Job Volume
screen, press the #4 key.
Unit Serial # Screen
The Unit Serial # screen shows
the sprayers serial number.
To select the Unit Serial #
screen, press the #4 key.
Timers Screen
The Timers screen shows the
total time the sprayer has been
turned on as well as the total
time the sprayer has been running (pumping).
ProSpray 30 • 34
SET MPa
23.0
ACTUAL MPa
22.5
USER PRE-SETS
SELECT-4
MENU-1
SELECT
PRE-SETS 1-4
MPa SETTING
5.2
SELECT-4
CHG-2
PRE-SET #1
5.2
PRESS +/- TO CHG
VOLUME PUMPED
SELECT-4
MENU-1
LITERS
XXXXXX
PRESS 1 FOR MENU
JOB VOLUME
SELECT-4
MENU-1
JOB LITERS
XXXX
MENU-1
RESET-3
UNIT SERIAL #
SELECT-4
MENU-1
SER # XXXXXXXXXX
PRESS 1 FOR MENU
TIMERS
SELECT-4
MENU-1
GB
To select the Timers screen,
press the #4 key.
Job Timers Screen
The Job Timers screen allows
the user to reset the "ON
TIME" and "RUN TIME" to
track time on specific jobs.
To select the Job TImers
screen, press the #4 key. The
screen will toggle between the
timers and a screen that allows the user to reset the timers.
Service Time Screen
The Service Time screen
allows the user to set a service
time interval (in hours). Below
the set time, the screens shows the current amount of hours on
the sprayer. To select the Service TImer screen, press the #4
key.
The screen will toggle between
the service hours and a screen
that allows the user to change
the service time interval.
When the service time interval is set and met by the run hours,
the display will toggle between the "Main screen" and a
"Service Required" screen at sprayer startup. To stop the
toggling, scroll to the "Service Time" screen and either set a
new service time interval or set the service time to "0".
Pressure Screen
The Pressure screen allows
the user to see the current set
point pressure as well as the
actual working pressure.
To select the Pressure screen,
press the #4 key. This screen
is also the Main Screen.
Security Code Screen
The Security Code screen
allows the user to set a four
digit security code to prevent
unauthorized use of the sprayer. If a security code has been
set, the control system display will ask for the code at startup.
If the correct code is entered, the display will show the Main
Screen and the sprayer will operate. If the wrong code is
entered, the display will continue to ask for the correct code
and the sprayer will be disabled. To set or change the security
code, press the #2 key.
If the sprayer is new, no security code is set
i
and the Main Screen will appear at startup. Al-
so, when setting a security code for the first
time, the "Enter Old Code Number" screen will
not appear.
Enter the old security code
number to access the screen
that allows the code change. If
the wrong code is entered, the display will continue to ask for
the correct code and the security code cannot be changed.
Enter the new security code.
Once the new code is entered,
the display will automatically
ask that the new code be re-entered for verification. If the same
new code is re-entered, the display will confirm that the new
code has been accepted and return to the Main Screen. If the
new code is re-entered incorrectly, the display will return to the
"Enter New Code Number" screen and the process will repeat.
Starting operation
ON TIME XXXXX:XX
RUN TIME XXXX:XX
JOB TIMERS
SELECT-4
MENU-1
ON TIME XXXXX:XX
RUN TIME XXXX:XX
SERVICE TIME
SELECT-4
MENU-1
SERVICE @
XXXHR
RUN HOURS
XX
PRESSURE
SELECT-4
MENU-1
SET MPa
23.0
ACTUAL MPa
22.5
SECURITY CODE
CHANGE-4
MENU-1
ENTER OLD CODE
NUMBER
ENTER NEW CODE
NUMBER