Electrical Connection - IFM Ecomat 100 EC2082 Mounting And Installation Instructions Manual

Inclination sensor

Advertisement

Available languages

Available languages

EC2082
INCLINATION SENSOR
Mounting
- 45°

Electrical connection

Description
Operating voltage
Ground
Analogue output
To protect the whole system the supply voltage must be protected with max.
0.5A.
The signal cable length is max. 30 m.
To ensure the accuracy of the inclination information additional screening may be
necessary.
8
PAGE
Pin
1
3
4
+45°
Fastening: M5 cylinder screw (to DIN 912)
Tightening torque: 1.8 Nm
Potential
20...30 V DC
GND
4...20 mA DC

Advertisement