Download Print this page

Technical Data - IFM Ecomat 100 EC2082 Mounting And Installation Instructions Manual

Inclination sensor

Advertisement

Available languages

Available languages

Contents

Technical data

Dimensions
Mounting
Electrical connection
Characteristics of the output function
Maintenance, repair and disposal
Declaration of conformity
Technical data
Order no.
Operating voltage
Current consumption max.
Analogue output
Output function
Load impedance
Short-circuit protection
Reverse polarity / overload protection
Angular range (α)
Zero error
Operating temperature
Protection
Housing material
Connection
Dimensions
41
EC2082
20...30 V DC
< 35 mA
current output 4...20 mA DC
I
= 12 mA + sin (α) x 8 mA
a
200...400 Ω (to signal ground at the output)
to U
and to ground
B
• / •
± 90°
< ± 7°
(the zero error can be reduced by ± 4°
by adjustment of the unit)
-30...+85°C
IP 67, II
plastic (Nyrol, PPE)
M12 connector; 4-pole; 0.2 m cable
52
EC2082
INCLINATION SENSOR
page 7
page 7
page 8
page 8
page 9
page 9
page 9
PAGE
7

Advertisement

loading