Page 2
The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
Electronic control system Air bleeding of hydraulic system Filter Flushing Maintenance Replacement of a coil Troubleshooting Extract from standards/directives User guide – Solenoid Type-examination certificate – Solenoid Declaration of conformity - Solenoid Mounting instruction cable gland D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
• Spool/sleeve and spool/body • High repeatability from valve to valve • Low hysteresis • Manual override • Optional: coil to permit ambient temperature up to +60 °C modification XG371 D1FB*0*EE D1FB*3*EE Spool/sleeve design Spool/body design D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
[m] 50 recommended With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. √ * Flow rate for different ∆p per control edge: ∆p · Nom. ∆p Nom. D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
Page 11
Coil to permit ambient XG371 temperature up to +60 °C Code Design Spool/sleeve design Spool/body design Code Solenoid 12 V / 2.3 A 24 V / 1.15 A J*XG371 24 V / 1.0 A D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
– typically approx. 10 % lower. Spool type E01H Spool type E01H*XG371 100 % 75 % 50 % 25 % Pressure drop p [bar] P–T All characteristic curves measured with HLP46 at 50 °C. D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
Page 13
– typically approx. 10 % lower. Spool type E01K Spool type E01K*XG371 100 % 75 % 50 % 25 % Pressure drop p [bar] P–T All characteristic curves measured with HLP46 at 50 °C. D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
In addition, clean the valve before starting such work, immediately. in particular removing dust, liquids and other depo- sits. Cleaning should be done using a lint-free cloth. Tools may not be used if they might cause a static charge on use. D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
• incorrect installation • unqualified operation • inadequate maintenance • use beyond specification Do not dismantle the valve. If you suspect a defect, return the valve to Parker. D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
12.9 to ISO 4762. age caused by careless transport. Docu- Parker can supply the correct screw sets, ment the transport damage and immediate- see the catalogue for order numbers.
DIN 51524 & 51502. Special gaskets may be available depending on the utilized fluid. In case of insecurity please consult Parker. The pressure fluid must have an ignition tempera- ture of at least 50 K above the maximum surface temperature of the valve (see EN 13463-5 and IEC 60079-4).
• Oil level in tank • Max. medium temperature If you are using the Parker PCD00A-400 digital module, make sure that the module • Max. surface temperature runs outside the Ex area or inside an electri- •...
Page 20
Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
• If you suspect that the valve is not moving Following any repair, commissioning must be car- freely, you should flush the valve with clean ried out as instructed. pressure fluid. D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
Page 22
Degrees of protection provided by enclosures (IP code) (IEC 60529:1989 + A1:1999 + A2:2013) BetrSichV Ordinance on industrial safety and health TRBS 2153:2009 Technical rules for operating safety Avoiding ignition hazards as a result of electrostatic charges D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...