Parker D1FB EE Series Operating Instructions Manual

Parker D1FB EE Series Operating Instructions Manual

Direct operated proportional dc valve, ii 2 g c t4 gb -20 degrees c ? ta ? +40 degrees c, -20 degrees c ? ta ? +60 degrees c
Hide thumbs Also See for D1FB EE Series:

Advertisement

Quick Links

Bulletin MSG11-5715-704/UK
Operating instructions
Series D1FB*EE
Design series 18
II 2 G c T4 Gb
-20 °C ≤ T
≤ +40 °C
a
D1FB*EEXG371:
-20 °C ≤ T
≤ +60 °C
a
Direct Operated
Proportional DC Valve
Parker Hannifin
Manufacturing Germany GmbH & Co. KG
Industrial Systems Division Europe
Gutenbergstr. 38
41564 Kaarst, Germany
Tel.: (+49) 181 99 44 43 0
E-mail: valvesisde@parker.com
Copyright © 2018, Parker Hannifin Corp.

Advertisement

Table of Contents
loading

Summary of Contents for Parker D1FB EE Series

  • Page 1 ≤ +60 °C Direct Operated Proportional DC Valve Parker Hannifin Manufacturing Germany GmbH & Co. KG Industrial Systems Division Europe Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+49) 181 99 44 43 0 E-mail: valvesisde@parker.com Copyright © 2018, Parker Hannifin Corp.
  • Page 2 The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
  • Page 3: Table Of Contents

    Electronic control system Air bleeding of hydraulic system Filter Flushing Maintenance Replacement of a coil Troubleshooting Extract from standards/directives User guide – Solenoid Type-examination certificate – Solenoid Declaration of conformity - Solenoid Mounting instruction cable gland D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 4: Ec Declaration Of Conformity

    Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof 0. EC declarations of conformity D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 5 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 6 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 7 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 8: Introduction

    • Spool/sleeve and spool/body • High repeatability from valve to valve • Low hysteresis • Manual override • Optional: coil to permit ambient temperature up to +60 °C modification XG371 D1FB*0*EE D1FB*3*EE Spool/sleeve design Spool/body design D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 9: Ordering Code

    [m] 50 recommended With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. √ * Flow rate for different ∆p per control edge: ∆p · Nom. ∆p Nom. D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 10 E01F E01H E01K E02F E02H E02K B31F 10 / 15 B31H 20 / 10 B31K 30 / 15 B32F 10 / 15 B32H 20 / 10 B32K 30 / 15 Code Spool position D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 11 Coil to permit ambient XG371 temperature up to +60 °C Code Design Spool/sleeve design Spool/body design Code Solenoid 12 V / 2.3 A 24 V / 1.15 A J*XG371 24 V / 1.0 A D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 12: Characteristic Curves

    – typically approx. 10 % lower. Spool type E01H Spool type E01H*XG371 100 % 75 % 50 % 25 % Pressure drop p [bar] P–T All characteristic curves measured with HLP46 at 50 °C. D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 13 – typically approx. 10 % lower. Spool type E01K Spool type E01K*XG371 100 % 75 % 50 % 25 % Pressure drop p [bar] P–T All characteristic curves measured with HLP46 at 50 °C. D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 14: Dimensions

    Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof Dimensions D1FB*C*EE D1FB*K*EE D1FB*E*EE Surface finish 4x M5x30 7.6 Nm BK375 SK-D1FB ISO 4762-12.9 ±15 % D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 15: Name Plate

    In addition, clean the valve before starting such work, immediately. in particular removing dust, liquids and other depo- sits. Cleaning should be done using a lint-free cloth. Tools may not be used if they might cause a static charge on use. D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 16: Important Information

    • incorrect installation • unqualified operation • inadequate maintenance • use beyond specification Do not dismantle the valve. If you suspect a defect, return the valve to Parker. D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 17: Installation

    12.9 to ISO 4762. age caused by careless transport. Docu- Parker can supply the correct screw sets, ment the transport damage and immediate- see the catalogue for order numbers.
  • Page 18: Electrical Connection

    DIN 51524 & 51502. Special gaskets may be available depending on the utilized fluid. In case of insecurity please consult Parker. The pressure fluid must have an ignition tempera- ture of at least 50 K above the maximum surface temperature of the valve (see EN 13463-5 and IEC 60079-4).
  • Page 19: Operating Instructions

    • Oil level in tank • Max. medium temperature If you are using the Parker PCD00A-400 digital module, make sure that the module • Max. surface temperature runs outside the Ex area or inside an electri- •...
  • Page 20 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 21: Troubleshooting

    • If you suspect that the valve is not moving Following any repair, commissioning must be car- freely, you should flush the valve with clean ried out as instructed. pressure fluid. D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 22 Degrees of protection provided by enclosures (IP code) (IEC 60529:1989 + A1:1999 + A2:2013) BetrSichV Ordinance on industrial safety and health TRBS 2153:2009 Technical rules for operating safety Avoiding ignition hazards as a result of electrostatic charges D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 23: A2 User Guide - Solenoid

    Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof A2. User guide – Solenoid D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 24 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 5715-645 DE.INDD CM Parker Hannifin Corporation...
  • Page 25: A3 Type-Examination Certificate - Solenoid

    Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof A3. Type-examination certificate – Solenoid D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 26 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 27 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 28 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 29 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 30 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 31 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 32 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 33 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 34 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 35 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 36 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 37 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 38 Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 39: A4 Declaration Of Conformity - Solenoid

    Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof A4. Declaration of conformity - Solenoid D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...
  • Page 40: A5 Mounting Instruction Cable Gland

    Direct Operated Proportional DC Valve Operating Instructions Series D1FB*EE Explosion Proof A5. Mounting instruction cable gland D1FB-EE 5715-704UK 07.01.19 Parker Hannifin Corporation...

This manual is also suitable for:

D1fb eexg371 seriesDesign 18 series

Table of Contents