Page 2
Parker or its subsid- iaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifica-...
Pursuant to European Directive 94/9/EC dated 23 March 1994 and statutory provisions relating to its implementation Dans le sens de la directive 94/9/CE datée du 23 3 1994 et des prescriptions légales promulguées quant à son application, Parker Hannifin GmbH Nous Gutenbergstraße 38...
Additionally spools with a P to T connection in the de-energized position need an external pressure supply (external inlet) or an integral check valve. D91VW D111VW D91VW D_W_EE_92 5715-681 UK.indd CM 07.05.13 Parker Hannifin Corporation Hydraulics Group...
Spring offset in position “b“. Operated in position “a“. Detent, operated in position “a“ or “b“. No center or offset position. Spring offset in position “a“. Operated in position “b“. D_W_EE_92 5715-681 UK.indd CM 07.05.13 Parker Hannifin Corporation Hydraulics Group...
Page 7
All sizes (D31, D41, D 91, D111) available Only D31, D41, D91 available. Not for D31DW and D111VW available. Not for spools 002, 009 available. Only D31, D41, D91 available. D_W_EE_92 5715-681 UK.indd CM 07.05.13 Parker Hannifin Corporation Hydraulics Group...
ISO 9461. Wiring min. [mm²] 3 x 1.5 recommended Wiring length max. [m] 50 recommended With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. D_W_EE_92 5715-681 UK.indd CM 07.05.13 Parker Hannifin Corporation Hydraulics Group...
D31NW Curve number Spool Code – – – – – – – – – – – – – – – – All characteristic curves measured with HLP46 at 50 °C. D_W_EE_92 5715-681 UK.indd CM 07.05.13 Parker Hannifin Corporation Hydraulics Group...
Page 10
P-port of the main valve. Direction- al valves with an integral check valve are available for the series D31NW and D41VW. Flow curve D31NW Flow curve D91VW D_W_EE_92 5715-681 UK.indd CM 07.05.13 Parker Hannifin Corporation Hydraulics Group...
Pilot Operated Proportional DC Valve Operating Instructions Series D*W*EE Explosion Proof Pilot oil inlet (supply) and outlet (drain) D31DW D31NW D41VW D91VW D111VW All orifice sizes for standard valves D_W_EE_92 5715-681 UK.indd CM 07.05.13 Parker Hannifin Corporation Hydraulics Group...
The system operator must monitor the tempera- circuit plans and Name plates must be observed and kept in a legible state. ture and cool the oil if necessary in order to the D_W_EE_92 5715-681 UK.indd CM 07.05.13 Parker Hannifin Corporation Hydraulics Group...
The manufacturer's warranty will not cover any re- 6 months varying air humidity, sulting damage. varying temperature < 35 °C Storage outside or in maritime or tropical climates leads to corrosion and may make the valve unusable. D_W_EE_92 5715-681 UK.indd CM 07.05.13 Parker Hannifin Corporation Hydraulics Group...
51502. Special sealing materials are supplied logue, property class 12.9 to ISO 4762. depending on the fluid used. Please ask the Parker can supply the correct screw sets, see factory if you are unsure. the catalogue for order numbers. The pressure fluid must have an ignition tempera- •...
Page 18
Pilot Operated Proportional DC Valve Operating Instructions Series D*W*EE Explosion Proof Size 10, mounting pattern ISO 4401-05-05-0-05 Size 16, mounting pattern ISO 4401-07-07-0-05 With * marked dimensions ± 0.1mm. All other dimensions ± 0.2mm. D_W_EE_92 5715-681 UK.indd CM 07.05.13 Parker Hannifin Corporation Hydraulics Group...
Page 19
Pilot Operated Proportional DC Valve Operating Instructions Series D*W*EE Explosion Proof Size 25, mounting pattern ISO 4401-08-08-0-05 Size 32, mounting pattern ISO 4401-10-09-0-05 With * marked dimensions ± 0.1mm. All other dimensions ± 0.2mm. D_W_EE_92 5715-681 UK.indd CM 07.05.13 Parker Hannifin Corporation Hydraulics Group...
flush the long pipes by short circuiting the pressure and return lines. This prevents the dirt occurring during instal- lation from being carried to the valve. D_W_EE_92 5715-681 UK.indd CM 07.05.13 Parker Hannifin Corporation Hydraulics Group...
Always think carefully about changing settings or removing components. Before starting work, check that the system was working correctly before the fault occurred. Following any repair, commissioning must be car- ried out as instructed. D_W_EE_92 5715-681 UK.indd CM 07.05.13 Parker Hannifin Corporation Hydraulics Group...
Electrical apparatus for use in the presence of combustible dust – Part 17: Inspection and maintenance of electrical installations in hazardous areas (oth- er than mines) (IEC 61241-17:2005) BetrSichV Betriebssicherheitsverordnung National industrial safety regulation and the enclosed Technical Regulations. D_W_EE_92 5715-681 UK.indd CM 07.05.13 Parker Hannifin Corporation Hydraulics Group...