Bulletin HY11-5715-669/UK
Operation Manual
Series D*FB / D*1FB with
Integrated Electronics
D*FB Design
12
D*1FB Design
10
Proportional Directional
Control Valve
Parker Hannifin GmbH
Hydraulic Controls Division
Gutenbergstr. 38
41564 Kaarst, Germany
Tel.:
+49-181 99 44 43 0
Fax:
+49-2131-513-230
E-mail: infohcd@parker.com
Copyright © 2010, Parker Hannifin GmbH
5 5

Advertisement

Table of Contents
loading

Summary of Contents for Parker DFB Series

  • Page 1 Series D*FB / D*1FB with Integrated Electronics D*FB Design D*1FB Design Proportional Directional Control Valve Parker Hannifin GmbH Hydraulic Controls Division Gutenbergstr. 38 41564 Kaarst, Germany Tel.: +49-181 99 44 43 0 Fax: +49-2131-513-230 E-mail: infohcd@parker.com Copyright © 2010, Parker Hannifin GmbH...
  • Page 2 final selection of the products and systems and assuring that all performance and safety requirements of the application are met. The products are subject to change by Parker Hannifin GmbH at any time without notice.
  • Page 3: Table Of Contents

    Individual Description of Expert Parameters Error messages Air Bleeding of Hydraulic System Filter Flushing 6. Maintenance 7. Trouble Shooting 8. Accessories / Spare Parts Accessories Spare Parts 9. Repair / Service 10. Additional Information D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 4: Introduction

    6 + PE Pot.-supply 4...20mA 12...20mA > P-A 6 + PE – Pot.-supply & 0...+/-10V 0...+10V > P-A 11 + PE command preset 4...20mA 12...20mA > P-A channel Factory set +/-10V D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 5: Order Code D*1Fb

    0...±20mA 0...+20mA > P-B 6 + PE — Pot.-supply 0...±10V 0...+10V > P-A & command 11 + PE 4...20mA 12...20mA > P-A preset channels Valve Code accessories Standard Monitor switch * as D1FV* separately available D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 6: Name Plate Example

    Series D*FB / D*1FB Name Plate Example Block Diagram of Integral Electronics Code F0/M0 (6+PE) Parker D*FB/D*1FB proportional directional control Code S0/G0 (6+PE) valves have an integral electronic and requires only one sole electrical common for the control system. Different flow sizes, as well as command signal op- tions are available to achieve an optimal adaption S0: 4...12...20mA...
  • Page 7: Technical Data

    Cable Specification mm² Codes F0, M0, S0, G0: 7 x 1.0 (AWG16) overall braid shield mm² Code W5: 11 x 1.0 (AWG16) overall braid shield Cable Length max. m 50 D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 8: Signal Flow Diagram

    Prop. Directional Control Valve Operation Manual Series D*FB / D*1FB Signal flow diagram D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 9: Safety Instructions

    6 months varying temperature < 35°C Outdoor storage or within sea and tropical climate will lead to corrosion and might disable the valve! D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 10: Mounting / Installation

    Prop. Directional Control Valve Operation Manual Series D*FB / D*1FB 4. Mounting / Installation Parker offers bolt kits: D1FB: BK375, D3FB: BK385, D31FB: BK385, Scope of Supply D41FB: BK320, D91FB: BK360, D111FB: Please check immediately after receiving the valve, BK386 if the content is matching with the specified scope...
  • Page 11: Electrical Connection

    Skinning lengths for the connecting cable: For the workmanlike termination of the crimp contacts the tool # 932 507-001 – supplier: Hirschmann – is required. Do not disconnect cable socket under tensi- D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 12: Electrical Interfacing

    It is necessary to use a low ohmic potential connection between control unit and machine frame to prevent earth loops (cross section AWG 6). D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 13 NAMUR is an association of users of process as well as free of inductive surges and mo- control technology. dulations. Due to the sensitivity of the valve a high signal quality is recommended, this will prevent malfunction. D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 14 +10 V -10 V of the potentiometer should be 5...10 k within a range of 5...10 kOhm. A nominal power rating of 0.1 W is sufficient. D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 15 D*1FB Wiring diagram of current command input +20...0...-20 mA Code G0 (6+PE) valve command signal function I D-E control system 0...+20mA I D-E D*1FB*G0 command signal I D-E 0...-20mA D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 16 Code W5 (11 + PE) control system valve command signal function command 12...20 mA signal 12 mA 4...12 mA actuator < 3.6 mA drive off actuator > 3.8 mA drive on D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 17 To prevent malfunctions a high signal The preset channels have priority against the analog quality is recommended. signal input for the external command. Wiring diagram of recall channels Code W5 (11 + PE) D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 18: Operation Instructions

    PC and electronic display may occur. via serial interface RS-232. Cable Specification Comfortable interface, see Parker freeware available The connection of the valve electronic to a PC from infohcd@parker.com. requires a special cable. It may be ordered under code 40982923.
  • Page 19: Parametrizing Connection

    Individual parameters may be selected via successful installation the desktop display shows mouse or the arrow buttons at the center of the the ProPxD icon for starting the program. program screen. D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 20 To prevent an unauthorized access for the expert mode, a pass word is requested. The name is “parker” and cannot be changed. Thus additionally to the button “Default” for loading of the default parameters, the button “Send parameter” appears in the “Expert”-operating mode.
  • Page 21: Parameter Overview For Basic Mode

    0 = ±10V cable break detection codes S0 & W5 – 0 = +/-10V command only 1 = 4-20mA 0 = 1% MIN operating threshold – 0 = 1% 1 = 0.01% D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 22: Individual Description Of Basis-Parameters

    4...20 mA. Adjustment of the MIN operating threshold. MIN operating threshold To match the response sensitivity for the MIN-stroke step. D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 23: Parameter Overview For Expert Mode

    To match the ramp functionality. ramp function Adjustment of the functionality for the internal command signals. internal command signal To match for the special option DFL. functionality D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 24: Error Messages

    file name.pxd already exists. The file name already exists within the indicated directory. Select Do you want to replace the another name, another directory or overwrite the existing file with file? “OK”. D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 25: Air Bleeding Of Hydraulic System

    It is recommended to flush the long pipelines by short circuiting the pressure and return lines, especially for large, central pressure oil stations. This prevents the installation dirt from entering the valve. D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 26: Trouble Shooting

    flow configuration incorrect correct pilot flow configuration only for D*1FB D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 27: Accessories / Spare Parts

    BK360 Code F0/M0/S0/G0: female connector 6+PE ordering code 5004072 Code W5: female connector 11+PE ordering code 5004711 Kaarst, Germany: Parker Hannifin GmbH Kaarst, Germany: Parker Hannifin GmbH D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
  • Page 28: Repair / Service

    Series D*FB / D*1FB 9. Repair / Service 10. Additional Information When you buy a Parker component, full techni- Our sales organisation is glad to advise you to cal support from Parker After Sales Service is hydraulic components and systems, filtration, con- included.