Individual Description of Expert Parameters Error messages Air Bleeding of Hydraulic System Filter Flushing 6. Maintenance 7. Trouble Shooting 8. Accessories / Spare Parts Accessories Spare Parts 9. Repair / Service 10. Additional Information D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
Series D*FB / D*1FB Name Plate Example Block Diagram of Integral Electronics Code F0/M0 (6+PE) Parker D*FB/D*1FB proportional directional control Code S0/G0 (6+PE) valves have an integral electronic and requires only one sole electrical common for the control system. Different flow sizes, as well as command signal op- tions are available to achieve an optimal adaption S0: 4...12...20mA...
6 months varying temperature < 35°C Outdoor storage or within sea and tropical climate will lead to corrosion and might disable the valve! D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
Prop. Directional Control Valve Operation Manual Series D*FB / D*1FB 4. Mounting / Installation Parker offers bolt kits: D1FB: BK375, D3FB: BK385, D31FB: BK385, Scope of Supply D41FB: BK320, D91FB: BK360, D111FB: Please check immediately after receiving the valve, BK386 if the content is matching with the specified scope...
Skinning lengths for the connecting cable: For the workmanlike termination of the crimp contacts the tool # 932 507-001 – supplier: Hirschmann – is required. Do not disconnect cable socket under tensi- D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
It is necessary to use a low ohmic potential connection between control unit and machine frame to prevent earth loops (cross section AWG 6). D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
Page 13
NAMUR is an association of users of process as well as free of inductive surges and mo- control technology. dulations. Due to the sensitivity of the valve a high signal quality is recommended, this will prevent malfunction. D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
Page 14
+10 V -10 V of the potentiometer should be 5...10 k within a range of 5...10 kOhm. A nominal power rating of 0.1 W is sufficient. D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
Page 15
D*1FB Wiring diagram of current command input +20...0...-20 mA Code G0 (6+PE) valve command signal function I D-E control system 0...+20mA I D-E D*1FB*G0 command signal I D-E 0...-20mA D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
Page 16
Code W5 (11 + PE) control system valve command signal function command 12...20 mA signal 12 mA 4...12 mA actuator < 3.6 mA drive off actuator > 3.8 mA drive on D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
Page 17
To prevent malfunctions a high signal The preset channels have priority against the analog quality is recommended. signal input for the external command. Wiring diagram of recall channels Code W5 (11 + PE) D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
PC and electronic display may occur. via serial interface RS-232. Cable Specification Comfortable interface, see Parker freeware available The connection of the valve electronic to a PC from infohcd@parker.com. requires a special cable. It may be ordered under code 40982923.
Individual parameters may be selected via successful installation the desktop display shows mouse or the arrow buttons at the center of the the ProPxD icon for starting the program. program screen. D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
Page 20
To prevent an unauthorized access for the expert mode, a pass word is requested. The name is “parker” and cannot be changed. Thus additionally to the button “Default” for loading of the default parameters, the button “Send parameter” appears in the “Expert”-operating mode.
4...20 mA. Adjustment of the MIN operating threshold. MIN operating threshold To match the response sensitivity for the MIN-stroke step. D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
To match the ramp functionality. ramp function Adjustment of the functionality for the internal command signals. internal command signal To match for the special option DFL. functionality D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
file name.pxd already exists. The file name already exists within the indicated directory. Select Do you want to replace the another name, another directory or overwrite the existing file with file? “OK”. D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
It is recommended to flush the long pipelines by short circuiting the pressure and return lines, especially for large, central pressure oil stations. This prevents the installation dirt from entering the valve. D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
flow configuration incorrect correct pilot flow configuration only for D*1FB D_FB-D_1FB 5715-669 UK.indd CM Parker Hannifin GmbH Hydraulic Controls Division...
Series D*FB / D*1FB 9. Repair / Service 10. Additional Information When you buy a Parker component, full techni- Our sales organisation is glad to advise you to cal support from Parker After Sales Service is hydraulic components and systems, filtration, con- included.