Cleaning and Disinfecting:

• Wipe the tip and probe with a cotton swab moistened with 70% isopropyl
alcohol before and after each use. After cleaning, wait at least 2 minutes
before taking a measurement for the unit to re-adjust to room temperature.
• Use only a soft dry cloth to clean the body of the thermometer (if necessary).
Never use an abrasive cleanser or submerge the thermometer in water or
other liquids.
Specifications
Feature performance / data:
Measurement location:
Measurement range:
Operation environment:
Storage environment:
Measurement readout:
Accuracy:
Display:
Battery:
Battery life:
Weight:
Dimensions:
Memory:
Auto shut off:
Case material:
Probe material:
Warranty:
Standards:
Complies with EN 12470-3 and ASTM E 1112-00
LIMITED WARRANTY
ADC warrants its products against defects in materials and workmanship under normal household use and service as follows:
1. Warranty service extends to the original retail purchaser only and commences with the date of delivery.
2. Your Adtemp TempleTouch Thermometer is warranted for two years from date of purchase.
What Is Covered: Replacement of parts, and labor.
What Is Not Covered: Transportation charges to ADC. Damages caused by abuse, misuse, accident, or negligence.
Incidental, special, or consequential damages. Some states do not allow the exclusion or limitation of incidental, special,
or consequential damages, so this limitation may not apply to you.
To Obtain Warranty Service: Send item(s) postage paid to ADC, Attn: Repair Dept., 55 Commerce Dr., Hauppauge,
NY 11788. Please include your name and address, phone no., proof of purchase, and a brief note explaining the problem.
Implied Warranty: Any implied warranty shall be limited in duration to the terms of this warranty and in no case beyond
the original selling price (except where prohibited by law). This warranty gives you specific legal rights and you may have
other rights which vary from state to state.
For Australian Consumers: Our goods come with guarantees that cannot be excluded under the Australian Consumer
Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonable foreseeable
loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and
the failure does not amount to a major failure.
Measurement time 6-8 seconds
Temple area of the forehead
95°F to 107.6°F (35°C to 42°C)
60.8°F to 104°F (16° C to 40° C)
Humidity: 15-95% (non condensing)
-4°F to 122°F (-20° C to 50° C)
Humidity: 15-95% (non condensing)
Celsius or Fahrenheit
Complies with ASTM E 1112-00 standard requirements
TN LCD 0.63" X 0.44" (16 mm X 11 mm)
2 AAA 1.5V batteries
Minimum 1000 full duty cycles over 24 month period
1.3 oz (37 gr) including batteries
4.7" x 1.17" x 1" (12 cm x 3.0 cm x 2.4 cm )
Last-reading display when turned on
After 60 seconds
Medical grade ABS plastic
Medical grade stainless steel, medical grade ABS plastic
2 year