4.3. Get Setting
The Get Setting command retrieves the reader's current settings.
Command:
<STX> <R> <ReviewID> <ETX> <LRC 1>
Response:
<ACK> <STX> <FuncID> <Len> <FuncData> <ETX> <LRC 2>
<FuncID>, <Len>, and <FuncData> retrieves the reader's current settings.
Example:
Review all settings:
CMD: \02\52\1F\03\4C
OUT: \06\02\7E\01\31\4C\01\31\58\01\31\03\5B
4.4. Function ID Table
The available Function IDs with the default setting are shown in bold.
Function Name
EncryptionID
SecurityLevelID
GetFirmwareVersion
4.4.1. EncryptionID
Set clear text:
CMD: 02 53 4C 01 30 03 2F
OUT: 06
Read EncryptionID:
CMD: 02 52 4C 03 1F
OUT: 06 02 4C 01 30 03 7C
Set Triple DES:
CMD: 02 53 4C 01 31 03 2E
OUT: 06
Read EncryptionID:
CMD: 02 52 4C 03 1F
Function ID Description
0x4C
Security Algorithm
'0' Clear Text
'1' Triple DES
'2' AES
0x7E
Security Level (Read Only) '0' ~ '3"
Default value '1'
0x22
Returns current firmware version
iMag, iMag Pro (II) User Manual