14 Configuration of the web server
4.
Event (zone attribute):
Zones can have very different attributes. The assignment is made according
to the type of trained detectors on the zone. The detector sends an alarm
notification to the alarm centre, which then triggers a reaction depending on
the set event properties and alarms.
The following alarm events can be defined:
Normal Alarm: When the alarm centre is activated, this zone triggers a
burglar alarm if one of the detectors has been triggered. Good examples
for this zone attribute include the training of motion detectors, magnetic
contacts or PIR network cameras.
Technical: One of the zones with this attribute triggers a technical alarm
when the alarm centre is deactivated and activated. Use this zone type
for flood detectors, for example.
Fire: This zone always triggers an alarm, irrespective of whether the
alarm centre is activated or deactivated. Use this zone attribute when
smoke detectors have been trained here.
Entry: If the burglar alarm centre is active, this zone triggers an alarm
following a specified delay time (entry delay). This zone attribute can be
used for a magnetic contact on the entrance door.
Set/Unset: A zone can be used for activation and deactivation with this
zone attribute.
Panic: This zone always triggers an alarm, irrespective of whether the
burglar alarm centre is activated or deactivated. Train panic detectors on
this zone, for example.
5.
Alarm (alarm reaction of the zone): Definition of which reaction is triggered
by an incoming event.
Deactivated: Alarm is deactivated, the event does not trigger an
alarm.
Burglary: Burglar alarm – can be signalled by an optical or acoustic
signaller. A corresponding alarm notification is also sent by e-mail,
depending on the settings.
Fire: Fire alarm – alarm is made by siren as pulsed alarm tone. A
corresponding alarm notification is also sent by e-mail, depending on
the settings.
Silent: Silent alarm – in the event of a silent alarm, the connected
acoustic and optical signalling devices are not activated. The alarm
notification is only sent by e-mail, depending on the settings.
Technical: Technical alarm – alarm made by siren. A corresponding
alarm notification is also sent by e-mail, depending on the settings.
To complete the configuration, click Apply.