System Power Up And Configuration; Configure Dmx; Set The Dmx Start Address; Dmx Loss Behavior - ETC GDS BluesSystem Installation Manual

Table of Contents

Advertisement

System Power Up and Configuration

This chapter provides details for system power up and configuration.
Note:
WARNING:

Configure DMX

Set the DMX Start Address

Set the DMX start address using the rotary encoders on the power supply board labeled DMX
Start Address.
The valid range is between 001 and 512 for the 1 zone power supply and between 001 and
506 for the 6 zone power supply.

DMX Loss Behavior

The DMX Power Supply has three options that can be set to change the behavior of the
output upon loss of DMX. These can be set and stored in the unit at any time during
installation or commissioning.
Step 1:
Step 2:
Address
901
Hold last look (default)
911
Channel to full on DMX loss
921
Channel fades down to 0% on DMX loss
Step 3:
Step 4:
21
Read this chapter in full before powering up the system.
A system without an accessible power disconnect device cannot be
serviced or operated safely. Follow all local codes and restrictions.
To set any of the DMX Loss Behavior options, ensure the power is switched to Off and
that a DMX source is connected to the unit.
Using the encoder wheels, set the address to any of the functions available in the table
below.
Function
Switch the power on. The DMX power supply will store the new DMX Loss Behavior
operating mode in memory.
Turn the power off and set the DMX start address for power supply operation. See
the DMX Start
Address.
100
10
1
DMX START ADDRESS
BluesSystem Installation Manual
Set

Advertisement

Table of Contents
loading

Table of Contents