MULTIQUIP GAW180HE Operation And Parts Manual page 28

Portable welder-generator, honda gx340k1ede2/gx340rt2ede2 gasoline engines
Table of Contents

Advertisement

NOTICE
Placing the idle control switch in the OFF position
(Figure 19) allows the engine to operate at a maximum
speed of about 3600 RPM's.
When the idle control switch is placed in the up position
ON position (Figure 20), the generator will run at idle
speed (2600 RPM's) until a load is applied, at that time
the engine speed will increase to 3600 RPM's as long
as a load is being applied.
When the load is not in use, the engine speed will drop
back to the idle mode after about 3 seconds.
Figure 20. Idle Control Switch (ON)
9. Place AC circuit breaker (Figure 21) in the ON position .
Figure 21. AC Circuit Breaker (ON)
PAGE 28 — GAW180HE/HEA WELDER-GENSET • OPERATION AND PARTS MANUAL — REV. #1 (10/01/19)
ON
OFF
25
ON
TEST
10. Read voltmeter on front panel of generator (Figure 22)
and verify that 120 VAC is displayed. Using an external
voltmeter as shown in Figure 22, verify that 120 VAC
is present at the 120V twist-lock and GFCI duplex
receptacles.
W
G
120VAC
X
L5-30R
120V
120
V
Figure 22. 120V Twist-Lock/GFCI Receptacles
11. If starting your welder-generator by the recoil start
method (no battery), grasp the starter grip (Figure 23)
and slowly pull it out. The resistance becomes the
hardest at a certain position, corresponding to the
compression point. Pull the starter grip briskly and
smoothly for starting.
Figure 23. Starter Grip
NOTICE
DO NOT pull the starter rope all the way to the end.
DO NOT release the starter rope after pulling. Allow it
to rewind as soon as possible..
12. Continue using the welder-generator referencing steps
6 through 10.
OPERATION
GFCI
120 VAC
OFF
V~
V
300 mV
A~
A
V
COM