Summary of Contents for Bartscher Master 900 Series
Page 1
GAS BRAISING PAN MOTORIZED GAS BRAISING PAN ELECTRIC BRAISING PAN MOTORIZED ELECTRIC BRAISING PAN SERIE 900 MASTER 296.600 296.670 296.680 295.6001 295.6701 295.6801 INSTALLATION, USE AND MAINTENANCE Pag. 29/55...
Page 4
CAT/KAT Made in E.U. G25.1 G110 G120 GAS/GAZ p mbar p mbar p mbar 28-30 28-30 3B/P p mbar 2E+3P p mbar 28-30 2E+3+ XXXX p mbar 2H3+ p mbar 2H3+ TIPO/TYPE p mbar 2E3P MOD. p mbar 2ELL3B/P ART. p mbar 2H3B/P N°...
Page 5
Figg.. – Abb. 9, 10, 11 : Sostituzione ugello bruciatore \ Changement du gicleur du brûleur \ Substituting the burner nozzle \ Austausch der Hauptbrennerdüse Fig. – Abb. 11 : Regolazione dell’aria primaria bruciatore \ Réglage de l'air primaire du brûleur \ Regulating the primary air of the burner \ Primärluftregelung des Hauptbrenners Fig.
Page 6
Fig. – Abb. 16 : Istruzioni uso (ribaltamento motorizzato) \ Instructions d’utilisation (relevage motorisé) \ Instruction for use (motorized) \ Bedienungsanleitungen (motorische kippung) Fig. – Abb. 17,18 : Sostituzione della valvola in sicurezza\ Changement du vanne de sécurité \ Substituting the safety valve\ Austausch der sicherheitsventil\ Fig.
Page 8
(Table 3) BURNER FEATURES (IS - CAT. I Normal Reduced Diam. Main By-pass Pilot Injectors Gas Type Capacity Capacity Injector Diameter Regulation [N°] [kW] [kW] [1/100 mm] [1/100 mm] “x” [mm] BRAISING PAN BURNER 1 UNIT Liquid Gas LPG 19.00 110 x 4 Close (G31)
Page 9
(Table 6) BURNER FEATURES (NL - CAT. II 2L3B/P Normal Reduced Diam. Main By-pass Pilot Injectors Gas Type Capacity Capacity Injector Diameter Regulation [N°] [kW] [kW] [1/100 mm] [1/100 mm] “x” [mm] BRAISING PAN BURNER 1 UNIT Liquid Gas LPG 19.00 110 x 4 Close...
Page 10
Table 8) BURNER FEATURES (CZ,SK,FI, LT, BG, NO, RO, EE, SI, HR, TR - CAT. II 2H3B/P Normal Reduced Diam. Main By-pass Pilot Injectors Gas Type Capacity Capacity Injector Diameter Regulation [N°] [kW] [kW] [1/100 mm] [1/100 mm] “x” [mm] BRAISING PAN BURNER 1 UNIT Liquid Gas LPG 19.00...
WARNINGS General • Read the instructions carefully before installation, use and maintenance of the appliance. • Installation must be carried out by qualified personnel following the manufacturer’s instructions in the specific manual. • The appliance must only be used by trained personnel and only for its intended use. •...
Declaration of compliance The manufacturer declares that the appliances of their production are compliant with the above mentioned EEC directives and requires that installation be done observing the norms in force, with particular regard to the system of fume evacuation and air exchange. DESCRIPTION OF APPLIANCES Gas Braising Pan A sturdy steel structure placed on four legs, which make it possible to regulate the height.
manufacturer's instructions and observing the norms in force, by qualified personnel, in compliance with the following provisions (GB): Gas Safety (Installation and Use) Regulations, 1984 Health and Safety at Work Act, 1974 Codes of Practice, BS6173, 1982 The Building Regulations, 1985 The Building Standards Regulations, 1981 For others countries follow the relevant local rules for: Gas board rules...
Page 14
on the bottom of the appliance, may be fixed or mobile using a compliant rapid pipe fitting. If flexible piping is used, this must be in stainless steel and compliant with the norm. All the seals on the junction threads must be in guaranteed materials certified for use with gas. Before the installation of each single appliance it is necessary to install a cut off cock for rapid interruption of the gas supply.
Page 15
Gas Type [mbar] [mbar] [mbar] G25 (Methane) G20 (Methane) G30 (Butane) G31 (Propane) G110 (Town Gas) G120 (Town Gas) If the pressure reading is not within the limits of the table, find out the cause. After solving the problem, check the pressure again. Checking the power Normally, it is sufficient to check that the nozzles installed are the correct ones and that the burners function properly.
Page 16
REGULATIONS AND SUBSTITUTION FOR USING A DIFFERENT GAS TO THE TYPE PROVIDED FOR Functioning with different gas to the type provided for. For changing to another type of gas it is necessary to substitute the nozzle in the main burners and in the pilot burner, following the indications given in the following paragraphs.
Page 17
INSTRUCTIONS FOR USE Gas Braising Pan (Fig. 13, pag.5) To switch on the braising pan burner, proceed in the following way: turn the knob (1) from the off position to the ignition position press the button hard; press the piezoelectric lighter button (2) to light the pilot burner;...
CARE AND MAINTENANCE OF THE APPLIANCE Cleaning ATTENTION! Before doing any cleaning, make sure that the appliance is disconnected from the electric mains and that the gas cut off valve is closed. During cleaning operations, avoid using direct or high-pressure sprays of water on the appliance. Cleaning must be done when the appliance is cold.
Page 19
preferable to screw the connections (9) to the valve interposing a clamping screw. Then replace the part. Thermocouple To replace the thermocouple, remove the water and gas knobs and the crank. Then remove the front panel by unscrewing the four screws that hold it in place. It is then necessary to unscrew the fitting of the thermocouple on the cock and the one on the pilot unit, then replace the part.
Need help?
Do you have a question about the Master 900 Series and is the answer not in the manual?
Questions and answers