3.29 TECHNICAL PARAMETERS FOR MIXED BOILERS (IN COMPLIANCE WITH REGULATION 813/2013).

The yields in the following tables refer to the higher heating value.
Model/s:
Condensing Boilers:
Low temperature boiler:
Boiler type B1:
Co-generation appliance for central heating:
Mixed heating appliance:
Element
Nominal heat output
For central heating only and mixed boilers: useful heat output
At nominal heat output in high tempera-
ture mode (*)
At 30% of nominal heat output in a low
temperature mode (**)
Auxiliary electricity consumption
At full load
At partial load
In standby mode
For mixed central heating appliances
Stated load profile
Daily electrical power consumption
Contact information
(*) High temperature mode means 60°C on return and 80°C on flow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return temper-
ature.
Model/s:
Condensing Boilers:
Low temperature boiler:
Boiler type B1:
Co-generation appliance for central heating:
Mixed heating appliance:
Element
Nominal heat output
For central heating only and mixed boilers: useful heat output
At nominal heat output in high tempera-
ture mode (*)
At 30% of nominal heat output in a low
temperature mode (**)
Auxiliary electricity consumption
At full load
At partial load
In standby mode
For mixed central heating appliances
Stated load profile
Daily electrical power consumption
Contact information
(*) High temperature mode means 60°C on return and 80°C on flow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return temper-
ature.
Victrix Pro 80 2ErP
SI
NO
NO
NO
SI
Symbol
Value
Unit
P
73
kW
n
P
73.0
kW
4
P
21.9
kW
1
el
0.119
kW
max
el
0.024
kW
min
P
0.004
kW
SB
Q
kWh
elec
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
Victrix Pro 100 2ErP
SI
NO
NO
NO
SI
Symbol
Value
Unit
P
90
kW
n
P
90.0
kW
4
P
27.0
kW
1
el
0.143
kW
max
el
0.017
kW
min
P
0.005
kW
SB
Q
kWh
elec
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
Fitted with supplementary heating system:
Element
Seasonal energy efficiency of central
heating
For central heating only and mixed boilers: useful efficiency
At nominal heat output in high tempera-
ture mode (*)
At 30% of nominal heat output in a low
temperature mode (**)
Other items
Heat loss in standby
Ignition burner energy consumption
Emissions of nitrogen oxides
Domestic hot water production efficiency
Daily gas consumption
Fitted with supplementary heating system:
Element
Seasonal energy efficiency of central
heating
For central heating only and mixed boilers: useful efficiency
At nominal heat output in high tempera-
ture mode (*)
At 30% of nominal heat output in a low
temperature mode (**)
Other items
Heat loss in standby
Ignition burner energy consumption
Emissions of nitrogen oxides
Domestic hot water production efficiency
Daily gas consumption
NO
Symbol
Value
Unit
η
91
%
s
η
87.5
%
4
η
96.0
%
1
P
0.143
kW
stby
P
0.000
kW
ign
mg /
NO
22
kWh
X
η
%
WH
Q
kWh
fuel
NO
Symbol
Value
Unit
η
92
%
s
η
88.0
%
4
η
96.8
%
1
P
0.145
kW
stby
P
0.000
kW
ign
mg /
NO
18
kWh
X
η
%
WH
Q
kWh
fuel