3.22 TECHNICAL PARAMETERS FOR MIXED BOILERS (IN COMPLIANCE WITH REGULATION 813/2013).

The yields in the following tables refer to the higher heating value.
Model/s:
Condensing Boilers:
Low temperature boiler:
Boiler type B1:
Co-generation appliance for central heating:
Mixed heating appliance:
Element
Nominal heat output
For central heating only and mixed boilers: useful heat output
At nominal heat output in high tempera-
ture mode (*)
At 30% of nominal heat output in a low
temperature mode (**)
Auxiliary electricity consumption
At full load
At partial load
In standby mode
For mixed central heating appliances
Stated load profile
Daily electrical power consumption
Contact information
(*) High temperature mode means 60°C on return and 80°C on flow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return tempera-
ture.
Model/s:
Condensing Boilers:
Low temperature boiler:
Boiler type B1:
Co-generation appliance for central heating:
Mixed heating appliance:
Element
Nominal heat output
For central heating only and mixed boilers: useful heat output
At nominal heat output in high tempera-
ture mode (*)
At 30% of nominal heat output in a low
temperature mode (**)
Auxiliary electricity consumption
At full load
At partial load
In standby mode
For mixed central heating appliances
Stated load profile
Daily electrical power consumption
Contact information
(*) High temperature mode means 60°C on return and 80°C on flow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return tem-
perature.
Hercules Condensing 26 3 ErP
SI
NO
NO
NO
Fitted with supplementary heating system:
SI
Symbol
Value
Unit
Element
Seasonal energy efficiency of central
P
24
kW
heating
n
For central heating only and mixed boilers: useful efficiency
At nominal heat output in high tempera-
P
23.9
kW
ture mode (*)
4
At 30% of nominal heat output in a low
P
7.9
kW
temperature mode (**)
1
Other items
el
0.031
kW
Heat loss in standby
max
el
0.014
kW
Ignition burner energy consumption
min
P
0.005
kW
Emissions of nitrogen oxides
SB
XL
Domestic hot water production efficiency
Q
0.283
kWh
Daily gas consumption
elec
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
Hercules Condensing 32 3 ErP
SI
NO
NO
NO
Fitted with supplementary heating system:
SI
Symbol
Value
Unit
Element
Seasonal energy efficiency of central
P
32
kW
heating
n
For central heating only and mixed boilers: useful efficiency
At nominal heat output in high tempera-
P
32.0
kW
ture mode (*)
4
At 30% of nominal heat output in a low
P
10.6
kW
temperature mode (**)
1
Other items
el
0.031
kW
Heat loss in standby
max
el
0.014
kW
Ignition burner energy consumption
min
P
0.005
kW
Emissions of nitrogen oxides
SB
XL
Domestic hot water production efficiency
Q
0.270
kWh
Daily gas consumption
elec
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
42
NO
Symbol
Value
Unit
η
90
%
s
η
86.1
%
4
η
95.8
%
1
P
0.167
kW
stby
P
0.000
kW
ign
mg /
NO
43
kWh
X
η
80
%
WH
Q
24.497
kWh
fuel
NO
Symbol
Value
Unit
η
92
%
s
η
87.2
%
4
η
96.7
%
1
P
0.175
kW
stby
P
0.000
kW
ign
mg /
NO
47
kWh
X
η
80
%
WH
Q
24.492
kWh
fuel