Immergas Victrix Pro 80 2ErP Instruction And Warning Book page 26

Hide thumbs Also See for Victrix Pro 80 2ErP:
Table of Contents

Advertisement

Error
Anomaly signalled
Code
0E2
Parasite flame block
0A13
Maximum N° of reset
0E25
P.C.B. error
DHW NTC probe in
0E32
short circuit
DHW NTC probe
outside the operating
0E33
range
Low power supply
0E34
voltage
Pressure or flow rate
0E37
insufficient system
Flue NTC probe in
0E45
short circuit
Flue NTC probe
outside the operating
0E46
range
Flow and return NTC
probe temperature
0E81
detection incorrect (in
stand-by)
Simple cascade com-
0E98
munication anomaly
Internal communica-
0E99
tion anomaly
(1) If the block or anomaly persists, contact an authorised company (e.g. Immergas Technical After-Sales Service).
(2) If normal operating conditions are restored, the boiler re-starts without having to be reset.
Error
Anomaly signalled
Code
FE94
Display board anomaly An error is detected on the display's P.C.B..
Shared common flow
FE95
probe short-circuited
or out of range
External probe
FE96
anomaly
FE97
Configuration error
(1) If the block or anomaly persists, contact an authorised company (e.g. Immergas Technical After-Sales Service).
(2) If normal operating conditions are restored, the boiler re-starts without having to be reset.
Cause
This occurs during the power-on phase in the event of a leak on the
detection circuit or anomaly in the flame control unit.
Number of allowed resets that have already performed.
An error is detected on the P.C.B. and the boiler does not start up
The board detects a short circuit on the DHW NTC probe
The board detects an open contact on the DHW NTC probe.
This occurs when the power supply voltage is lower than the allowed
limits for the correct boiler operation.
If the system pressure is too low the boiler switches off.
The board detects a short circuit on the flue NTC probe.
The board detects an open contact on the flue NTC probe.
With the boiler in stand-by, the board detects an anomalous difference
between the NTC probe flow and return temperatures. The error may
be caused by a failure in one of the two probes
Occurs if the communication between the display boards breaks down
A communication error has been detected between the display board
and the boiler's P.C.B.. In the event of simple cascade, even in the case
of a communication error between the display boards.
Cause
The board detects an incorrect value on the flow NTC probe or "P38"
parameter not set correctly..
An anomaly is detected on the external probe.
P.C.B. configuration error.
This may happen when the P.C.B. is changed It may occur also in the
event of replacement of the electronic boards with an incorrect model..
26
Boiler status / Solution
(2) (1)
Attention: it is possible to reset the anom-
aly up to 5 consecutive times within 15
minutes. (1) By switching the appliance
on and off the 5 attempts are re-acquired.
(2) (1)
(2) (1)
(2) (1)
(2) (1)
Check on the boiler pressure gauge (1)
that the system pressure is between 1÷1.2
bar and restore the correct pressure if
necessary.
(2) (1)
(2) (1)
(2) (1)
(2) (1)
Check the bus' electric connection.
Perform the Auto detection.
Check whether the software versions
match.
(2) (1)
Check the boiler's wiring.
Check the bus' electric connection.
Perform the Auto detection in the event
of simple cascade installation.
(2) (1)
Boiler status / Solution
(2) (1)
(2) (1)
Check the boiler configuration, check
the external probe (2) (1)
Check the configuration parameters.
Perform the Auto detection.
(2) (1)

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Victrix Pro 80 2ErP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Victrix pro 100 2erpVictrix pro 120 2erp

Table of Contents