3.24 TECHNICAL PARAMETERS FOR MIXED BOILERS (IN COMPLIANCE WITH REGULATION 813/2013).

The yields in the following tables refer to the higher heating value.
Model/s:
Condensing Boilers:
Low temperature boiler:
Boiler type B1:
Co-generation appliance for central heating:
Mixed heating appliance:
Element
Nominal heat output
For central heating only and mixed boilers: useful heat output
At nominal heat output in high tempera-
ture mode (*)
At 30% of nominal heat output in a low
temperature mode (**)
Auxiliary electricity consumption
At full load
At partial load
In standby mode
For mixed central heating appliances
Stated load profile
Daily electrical power consumption
Contact information
(*) High temperature mode means 60°C on return and 80°C on flow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return tempera-
ture.

3.25 PRODUCT DATA SHEET (IN COMPLIANCE WITH REGULATION 811/2013).

Victrix Zeus 26 2 ErP
A
++
A
A
+
B
A
A
C
B
D
C
D
E
E
F
F
G
G
24
kW
53
dB
Victrix Zeus 26 2 ErP
Symbol
Value
Unit
P
24
n
P
23.6
4
P
7.1
1
el
0.046
max
el
0.022
min
P
0.008
SB
XL
Q
0.238
kWh
elec
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
XL
A
For proper installation of the appliance refer to chapter 1 of this booklet (for the in-
staller) and current installation regulations. For proper maintenance refer to chapter
3 of this booklet (for the maintenance technician) and adhere to the frequencies and
methods set out herein.
SI
NO
NO
NO
Fitted with supplementary heating system:
SI
Element
Seasonal energy efficiency of central
kW
heating
For central heating only and mixed boilers: useful efficiency
At nominal heat output in high tempera-
kW
ture mode (*)
At 30% of nominal heat output in a low
kW
temperature mode (**)
Other items
kW
Heat loss in standby
kW
Ignition burner energy consumption
kW
Emissions of nitrogen oxides
Domestic hot water production efficiency
Daily gas consumption
Parameter
Yearly energy consumption for the heating function (Q
Yearly electricity consumption for the domestic hot water function
(AEC)
Yearly fuel consumption for the domestic hot water function (AFC)
Seasonal room heating yield (η
)
s
Domestic hot water production yield ( η
33
Symbol
Value
η
92
s
η
87.5
4
η
97.2
1
P
0.086
stby
P
0.000
ign
NO
47
X
η
82
WH
Q
23.660
fuel
)
41,8 GJ
HE
52 kWh
)
wh
NO
Unit
%
%
%
kW
kW
mg /
kWh
%
kWh
value
18 GJ
92 %
82 %