3.22 TECHNICAL PARAMETERS FOR MIXED BOILERS (IN COMPLIANCE WITH REGULATION 813/2013).

The yields in the following tables refer to the higher heating value.
Model/s:
Condensing boiler:
Low-temperature boiler:
B1 boiler:
Cogeneration space heater:
Combination heater:
Item
Rated heat output
For boiler space heaters and boiler combination heaters: useful heat
output
At rated heat output and high-tempera-
ture regime (*)
At 30 % of rated heat output and low-
temperature regime (**)
Auxiliary electricity consumption
At full load
At part load
In standby mode
For combination heaters:
Declared load profile
Daily electricity consumption
Contact details
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature.

3.23 PRODUCT DATA SHEET (IN COMPLIANCE WITH REGULATION 811/2013).

VICTRIX SUPERIOR 32 X 2 ErP
A
++
A
+
A
A
B
C
D
E
F
G
51
dB
Victrix Superior 32 X 2 ErP
Symbol
Value
P
32
n
P
32,0
4
P
9,6
1
el
0,043
max
el
0,010
min
P
0,005
SB
Q
elec
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
32
kW
YES
NO
NO
NO
Equipped with a supplementary heater:
NO
Unit
Item
kW
Seasonal space heating energy efficiency
For boiler space heaters and boiler combination heaters: Useful efficiency
At rated heat output and high-tempera-
kW
ture regime (*)
At 30 % of rated heat output and low-
kW
temperature regime (**)
Other items
kW
Standby heat loss
kW
Ignition burner power consumption
kW
Emissions of nitrogen oxides
Water heating energy efficiency
kWh
Daily fuel consumption
Parameter
Yearly energy consumption for the heating function (Q
Yearly electricity consumption for the domestic hot water function
(AEC)
Yearly fuel consumption for the domestic hot water function (AFC)
Seasonal room heating yield (η
)
s
Domestic hot water production yield ( η
For proper installation of the appliance refer to chapter 1 of this booklet (for the in-
staller) and current installation regulations. For proper maintenance refer to chapter
3 of this booklet (for the maintenance technician) and adhere to the frequencies and
methods set out herein.
39
Symbol
Value
η
91
s
η
88,4
4
η
96,0
1
P
0,077
stby
P
0,000
ign
NO
27
X
η
WH
Q
fuel
)
HE
)
wh
NO
Unit
%
%
%
kW
kW
mg /
kWh
%
kWh
value
1,5 GJ
---
---
91 %
---