 VISCA RS-422 OUT terminal
When you connect multiple cameras,
connect it to the VISCA RS-422 IN terminal of
the next camera in the daisy chain
connection.
 IR SELECT switch
Select the camera number when you operate
multiple cameras with the same remote
commander.
Remote commander sensor
This is for the supplied remote commander.
 SYSTEM SELECT switch
Used for selecting the video signal format to
be output from the HDMI OUT and SDI OUT
terminals.
For details, see "SYSTEM SELECT switch
settings" (page 92).
 Reset switch
Press the switch for 5 seconds or longer to
return to the factory default.
(earth) terminal
 AC adapter cord clamper
Fix the cord of an AC adapter with the cord
clamper so that it does not come out.
 MIC terminal (audio input terminal)
Input for commercially-available MIC or LINE
to connect an audio device.
* Switch between MIC and LINE input, as indicated
on "Connecting to commercially-available
microphones etc." (page 25).
 CAMERA SETUP switches
SDI format/level settings
Set the RS-422 baud rate for VISCA
communication.
CAMERA SETUP switch settings
Switch No.
1
2
3
4
 SDI format/level settings
This setting is enabled when the signal
format is 1920×1080/50p or 1920×1080/
59.94p.
Switch state
ON
OFF
* Turn the power off or to standby, then turn
the power on to reflect the changes after
setting.
 Termination setting of external
synchronization
Use this setting during external
synchronization (page 24).
When you use the external
synchronization while multiple cameras
are connected, turn OFF when this
camera is in the middle of a daisy chain
connection and turn ON when this
camera is at the end.
When nothing is connected to the EXT
SYNC terminal, turn ON.
Switch state
ON
OFF
* The setting is applied instantly.
 HTTP/RTSP communication usage setting
Use this setting when you set the HTTP/
RTSP protocol setting.
Turn ON to forcibly enable the setting.
Turn OFF to configure the setting
according to the OSD menu.
Switch state
ON
OFF
* Turn the power off and on to reflect the
changes after setting.
9
Setting items
Setting up 3G-SDI level
Termination setting of external
synchronization
HTTP/RTSP communication
usage setting
Baud Rate settings of RS-422
for VISCA communication
SDI format/level
Level-B
Level-A
TERMINATION
TERMINATE
OPEN
HTTP/RTSP CONNECTION
FORCED ON
MENU